BURNER AND BASKET (TUMBLER)/LINT CHAMBER
MANUAL RESET HI-LIMIT INSTRUCTIONS
MANUAL RESET HI-LIMIT INSTRUCTIONS
FOR DUAL TIMER OR PHASE 5 WITHOUT HEAT FAULT
This dryer was manufactured with a burner manual reset hi-limit and basket (tumbler)/lint chamber hi-limit
thermostat. If either burner manual reset hi-limit thermostat is open prior to the start of the drying cycle, or
during the cycle, the dryer will not recognize the open state of the burner hi-limit thermostat and will start or
continue through the drying cycle with no heat. Manual reset hi-limit thermostat must be reset manually.
This hi-temperature condition may be caused due to a restricted exhaust, poor airflow, or improper burner oven
operation.
The location of the manual reset hi-limit switch is on the left side of the burner box and the basket (tumbler)
hi-limit is located in the lint chamber area.
WARNING: Discontinue power to the dryer before attempting to reset hi-limit.

SECTION XI

I M P O R T A N T

(GAS MODELS ONLY)

IMPORTANT
This dryer is equipped with a burner hi-
limit and tumbler/lint chamber hi-limit
thermostat which must be reset manually.
WARNING: Discontinue power to dryer
before attempting to reset hi-limit.