H. STEAM INFORMATION
It is your responsibility to have ALL steam plumbing connections made by a qualified professional to assure that
the installation is adequate and conforms with local and state regulations or codes.
IMPORTANT: Failure to comply with the requirements stipulated in this manual can result in
component failure which will VOID THE WARRANTY.
NOTE: The dyer is manufactured with a pneumatic (piston) damper system which requires an external
supply of clean, dry, regulated air (0.75 cfh [0.02 cmh] 80 PSI ± 10 PSI [5.51 bar ± 0.68
bar]). Refer to Steam Damper Air System Connections , Section H, item 4.
1. Steam Coil PH Level
The normal PH level for copper type steam coils must be maintained between a value of 8.5 to 9.5. For
steel type steam coils the PH level must be maintained between a value of 9.5 to 10.5. These limits are set
to limit the acid attack of the steam coils.
IMPORTANT: Coil failure due to improper PH level will VOID THE WARRANTY.
2. Steam Requirements - High Pressure
Inlet --------1-1/4" supply line connection -- quantity one (1) at top manifold.
Return -----1-1/4" return line connection -- quantity one (1) at bottom manifold.
OPERATING STEAM PRESSURE
Maximum
Minimum
Heat Input (Normal Load)
Consumption (Approximate) @ 125 PSI
Shaded areas are stated in metric equivalents
* Minimum operating pressure for optimum results.
3. Installation Instructions
To insure that an adequate supply of steam is provided, be sure that the steam supply lines and steam return
lines are sized and laid out as stipulated in this manual. Inadequate steam supply lines and steam return
lines are sized and laid out as stipulated in this manual. Inadequate steam supply and steam return lines or
improper steam plumbing will result in poor performance and can cause component failure. Clean, dry,
regulated steam must be provided to the dryer.
IMPORTANT: Steam coil failure due to water hammer by wet steam will VOID THE WARRANTY.
125 psig
100 psig*
11 Bhp
375
lbs/hr
34
862 kPa
689 kPa
170
kg/hr