(1) System Reset caused by CPU Runaway (Re-start Procedure)
Error Code
Possible cause of
the malfunction
Countermeasures
Note
Installation Manual
1000: Hard WDT overflow
1001: Illegal interrupt
1002: Soft WDT overflow
1.
External circumstance, such as induction noise
2.
Hardware is defective.
3.
The CPR software is terminated by executing illegal instruction.
4.
The CPR software is terminated by executing infinite loop.
Does the trouble occur frequently?
Yes
Re-program the system programming data.
No change in
condition
No change in
condition
No change in
condition
Remove the LPR cards one by one.
No change in
condition
No change in
condition
Consult the Service Center.
*It is recommended to have a current copy of the program on disk to
facilitate accurate and rapid recovery.
Replace the CPU card.*
Replace the TSW card.
Replace the Shelf.
End
Troubleshooting
No
OK
OK