Panasonic KX-TD500 Installation Manual page 260

Digital super hybrid system
Hide thumbs Also See for KX-TD500:
Table of Contents

Advertisement

Utility
Error Code
Error Message
#1105
Expansion shelf 1 heat
alarm
#1106
Expansion shelf 2 heat
alarm
#1107
Basic shelf fan alarm
#1108
Expansion shelf 1 fan alarm The fan of Expansion shelf 1 gets out of order.
#1109
Expansion shelf 2 fan alarm The fan of Expansion shelf 2 gets out of order.
#1110
Calendar IC R/W stop
#1111
Calendar IC stop
#1112
CPU RAM battery alarm
Error Code
Error Message
#1200
Basic shelf AC power down The Basic shelf AC power malfunction occurs for the
#1201
Expansion shelf 1 AC
power down
#1202
Expansion shelf 2 AC
power down
260
Error Log (Major)
The heat of the power supply of Expansion shelf 1
exceeds the limit.
The heat of the power supply of Expansion shelf 2
exceeds the limit.
The fan of Basic shelf gets out of order.
The calendar IC R/W of CPU card is defective.
The calendar IC of CPU card is defective.
The CPU RAM battery alarm occurs because of defective
lithium battery on the CPU card or defective CPU card.
Error Log (Minor)
following reasons.
a)
AC power cord is unplugged.
b)
Power Failure
c)
Malfunction of Power Supply Unit of the Basic
Shelf or the trouble with the Power Supply System
(Backboard, CPU card) of the Shelf
The Expansion shelf 1 AC power malfunction occurs for
the following reasons.
a)
Power Failure
b)
Malfunction of Power Supply Unit of the
Expansion Shelf 1, or the trouble with the Power
Supply System (Backboard, CPU card) of the
Shelf
The Expansion shelf 2 AC power malfunction occurs for
the following reasons.
a)
Power Failure
b)
Malfunction of Power Supply Unit of the
Expansion Shelf 2, or the trouble with the Power
Supply System (Backboard, CPU card) of the
Shelf
Cause
Cause
Installation Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Td500Kx-td520

Table of Contents