Design Guide (For Zids240); The Installation Space; Product Clearances; Side-By-Side Installations - Monogram ZIDI240 Design And Installation Manual

Double-drawer built-in refrigerator
Table of Contents

Advertisement

FOR MODEL ZIDS240 WITH STAINLESS STEEL DRAWERS AND HANDLES

THE INSTALLATION SPACE

IMPORTANT: Double-Drawer Refrigerators are
designed to be built-in only. They cannot be used
free-standing.
Locate
Outlet
8-1/2"
10-1/2"
9"
9" Max.
34-1/2"-35"
Max.
1-1/2"
1-1/2"
23-3/4" Min.
NOTE:
Handle and
handle standoff
depth is 2-1/8"
The cutout depth should be 24"
NOTE: The unit is designed to be flush with the
surrounding cabinets.
Additional Specifications
• A 120 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install a
properly grounded 3-prong electrical receptacle
recessed into the back wall as shown. Electrical must be
located on rear wall as shown. NOTE: GFCI (ground
fault circuit interrupter) is not recommended.
SIDE-BY-SIDE INSTALLATIONS –
Stainless Steel Models Only
For a complete refreshment center, install a Double-Drawer
Refrigerator beside a Beverage Center, Wine Chiller/
Wine Reserve, Fresh-Food Refrigerator or Bar Refrigerator
with Icemaker.
• A side-by-side installation requires at least a 47-1/2" wide
opening. No trim kits required.
• Products must operate from separate, properly grounded
receptacles.
Design Guide
24"
23-3/4"
25-7/8"
34-1/2"
Including
Handles
23-3/4"

PRODUCT CLEARANCES

When installed
in a corner:
Allow 2-1⁄2" min. clearance between Double-Drawer
and adjacent cabinet, wall or other appliances.
Allow 22" min. clearance from the front for drawer
opening.
NOTE: Clearances are based on the noted 2-1⁄8"
handle standoff depth.
• Test the drawer openings. Carefully open and close
the drawers. The drawers should not rub or catch
on adjacent cabinetry. Notify the installer if the
drawers make contact with cabinetry.
Choose the location:
• These products may be closed in on the top and
three sides as long as the front is unobstructed for
air circulation and proper access to the drawers.
• Do not install these products where the temperature
will go below 55°F (13°C) or above 90°F (32°C).
• These products are not designed to be stacked one
over the other.
34-1/2"-35"
4
Countertop
Double-Drawer
Clearance for Door
Opening 2-1/2" min.
Locate
Outlet
10-1/2"
10-1/2"
14"
24"
9"
9"
15"
1-1/2"
47-1/2" Min.
22" min.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zids240