CLEARANCES
These units are equipped with a 3-position door stop.
The factory set 115° door swing can be adjusted to 90° if
clearance to adjacent cabinets or walls is restricted.
When Installed into a corner:
Allow 15" for a full 115° door swing and pan removal.
Allow 4" min. clearance when door swing is adjusted
to a 90° opening for pan access, but pan removal is
restricted.
INSTALLATION
ZUG2 Unified Grille Panel Kit
• If you are installing two units, side by side, the installation
space must be 75" wide.
Note: Additional cutout width may be required when side panels
are used. Add side panel thickness to the finished cutout to
calculate rough-in width.
• The water and electrical locations for each product must be
located as shown.
• A separate 115V, 60Hz., 15 or 20 amp power supply is
recommended for each product.
Note: When implementing a dual installation, the factory
installed standard case trim should be used on the handle side
of each unit and the supplied flush case trim should be used on
the hinge side of each unit.

CUSTOM HANDLE DESIGN GUIDE

Custom handles must be used for flush installation. For
custom handle installation, counterbore holes in rear of
decorative panels must ensure 1/2" material thickness
remains for handle support.
NOTE: The counterbore must not exceed 1" in
diameter.
1/2"
1/4"
3/4"
Design Guide - Flush Installation
4" Min. to Wall
90° Door Swing
15"
Min. to
Wall
38-3/4"
Clearances for Multiple Single Door Installations
In a side-by-side installation of a left and right door swing
product, a 1" clearance between the units is required.
Order ZUG2 Unified Grille Panel Kit for one continuous
grille panel.
85"
Finished
Opening
Minimum distance from handle
side edge to handle center should
be 3-1/2" as shown.
7/8"
24
1"
115° Door
115° Door
Swing
Swing
75" Finished Width
4-5/16"
Electrical
5-1/2"
5-1/2"
9"
9"
26-3/16" Minimum
Cutout Depth
Cold Water
Cold Water
Suppl
Suppl
3-1/2"
3-1/2"
3-1/2"
7"
7-1/2" 7-1/2"
3-1/2"
3-1/2"
3-1/2"
3-1/2" 3-1/2"
0.85"
1/2"
15"
Min. to
Wall
Wall View
24-3/16"
Electrical
Area
3-1/2"
7"
3-1/2"
3-1/2"