Dimensions of top heats:
It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not build
up on or within the fixture. Otherwise, the fixture's light-output will be significantly reduced. Regular cleaning will
not only ensure the maximum light-output, but will also allow the fixture to function reliably throughout its life.
A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances
should alcohol or solvents be used!
The front objective lens will require weekly cleaning as smoke-fluid tends to building up residues, reducing the
light output very quickly. The cooling fans and airt vents should be cleaned monthly.
The interior of the fixture should be cleaned at least annually using a vacuum-cleaner or an air-jet.
The dichroic colour filters should be cleaned monthly.
There are no serviceable parts inside the device except for the lamp and the fuse.
Please refer to the instructions under "Fitting/Exchanging the lamp".
Maintenance and service operations are only to be carried out by authorized distributors.
Replacing the fuse
If the lamp burns out, the fine-wire fuse of the device might fuse, too. Only replace the fuse by a fuse of same
type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
1) Unscrew the fuseholder on the rear panel of the base with a fitting screwdriver from the housing
(anti - clockwise).
2) Remove the old fuse from the fuseholder.
3) Install the new fuse in the fuseholder.
4) Replace the fuseholder in the housing and fix it.
Specifications are subject to change without notice.

13. Maintenance and cleaning

DANGER !
Disconnect from the mains before starting any
maintenance work
34