Resetable Hours - The function shows the number of the operation hours with the lamp
on that the ColorWash 575E AT has been powered on since the counter was last reset. In
order to reset this counter to 0, press [ENTER] twice.
Lamp Strikes - Select this submenu to read the total number of the lamp strikes.
Total Hours - The function shows the total number of the lamp strikes since the ColorWash
575E AT has been fabricated.
Resetable Hours - The function shows the number of the lamp strikes since the counter was
last reset.In order to reset this counter to 0, press [ENTER] twice.
Fixture Temperatures --- Select this submenu to read the temperatures of the fixture:
Current - Select this function to read the current temperatures of the fixture inside (Board
Maximum nonresetable - The function shows the max.temperatures of the fixture inside
(Board Temp.,Head Temp..) since the ColorWash 575E AT has been fabricated.
Maximum resetable - The function shows the maximum temperatures of the fixture inside
(Board Temp.,Head Temp.) since the respective counter was last reset.In order to reset de-
sired counter to 0,press [ENTER] twice.
Measurement points:
Please note that the ambient temperature should not exceed 40°C.
DMX Values
--- Select this function to read DMX values of each channel received by the fixture.
Product IDs
--- Select this function to read the MAC address or the RDM UID number.
Software Version --- Select this function to read the software version of the fixture modules:
IC1 B.--- Main processor on the main board in the fixture base
IC2 B .--- Pan processor on the main board in the fixture base
IC3 B. --- Tilt procesor on the main board in the fixture base
IC4 B.--- EEprom on the main board in the fixture base
IC1 L.--- Processor 1 in the left arm of the fixture
IC2 L.--- Processor 2 in the left arm of the fixture
IC1 R.--- Processor 1 in the right arm of the fixture
IC1 DS--- Display processor on the display module in the fixture base
IC2 DS--- Memory on the display module in the fixture base

8.3 Personality

Use this menu to to modify ColorWash 575E AT operating behavior.
User mode --- ColorWash 575E AT allows you to recall up to 3 user settings.After switching the fixture on for
the first time, the User A settings are active.All changes made in "Personality" menu ,"Fixture Address" menu
and Music Trigger and Presetting Playback functions from "Stand-alone setting" menu are saved to the User
A settings.If you now set the User B settings active,from this moment these changes are saved to the User
B settings.After switching the fixture off and on ,the User B setting is active.In this way you may use 3 fixture
operating behaviour.
User A Settings --- The function recall the user A settings.
User B Settings --- The function recall the user B settings.
User C Settings --- The function recall the user C settings.
Pan Reverse --- Select this function to invert the pan movement.
Tilt Reverse --- Select this function to invert the tilt movement.
DMX Preseting --- Select this function to set desired effects assigning to the channels.Please refer to the
Temp.,Head Temp.)
Board Temp. - temperature on the main board in the fixture base.
Temperatures below 66°C are not critical. 66° C and more lead to the lamp
being switched off and the fixture goes to "low power mode".Before switching
the lamp on again (after 5 minutes),run a total fixture reset.
Head Temp. - temperature of the head inside.Temperatures below 66°C are
not critical.66° C and more lead to the lamp being switched off and the fixtu-
re goes to "low power mode". Before switching the lamp on again (after 5
minutes),run a total fixture reset.