Replacing Fan Trays - HP 5400zl Series Installation And Getting Started Manual

Procurve series 5400zl switches
Hide thumbs Also See for 5400zl Series:
Table of Contents

Advertisement

Replacing Components

Replacing Fan Trays

Replacing Fan Trays
When a fan fails the Fan Status LED on the switch chassis will blink
simultaneously with the switch Fault LED. In this case, the entire fan tray
needs to be replaced. You cannot replace individual fans.
The fan tray is hot swappable. It can be removed and replaced without
removing power from the switch. However, install the new fan tray
immediately (within two minutes) after removing the old fan tray to avoid
overheating and switch shutdown (within three minutes).
Although these procedures show the 6-slot chassis, the procedures are the
same for the 12-slot chassis.
W A R N I N G
To avoid contact with spinning fans, if you are hot swapping out the
fan tray assembly, pull the assembly out one-inch and allow the fans
to stop rotating (approximately 20 seconds) before pulling it all the
way out.
To replace a fan tray:
1.
2.
Figure 4-3. Fan Tray Removal and Installation
4-4
Using either a flat-bladed or Torx T-10 screwdriver loosen the retaining
screws holding the fan tray assembly and pull the fan tray assembly out.
Install the new fan tray assembly and tighten the retaining screws.
Handle
Retaining Screws