<Files to be obtained>
- IPLog_yyyymmddhhmmss.log: Controller log
- XXXXX.spl: Print data (The latest 10 jobs are captured.)
* Several files other than the above are stored depending on the condition.
* A part of log file name "yyyymmdd_hhmmss" describes the following.
yyyy: year mm: month dd: day hh: hour mm: minute ss: second
Ex. 20090204_152230--> This file was captured at 15:22:30 on February 2, 2009.
7. Be sure to turn the main power switch (SW1) OFF and ON after removing the USB memory
from the USB port. If it is not turned OFF and ON, there will be no guarantee for its proper
operation after the log acquisition is completed.
8. Compress the files copied to the PC to be sent to KMBT.
2.1 Procedure of acquisition of the controller capture
<<Timing of connecting USB memory to the USB port on the IC-board and getting captured file>>
Before the symptom occurs.
1. Obtain a key file for acquisition of controller capture from
Or create a key file. (A key file can be created from a Notepad.)
Key file format
HDDorUSB, type
MIO, switch, count
NET, switch, count
RIP, switch, count
PDL, switch, count
TIF, switch, count
- MIO: Data received from the network
- NET: Data analyzed with PrintJobAnalyzer
- RIP: Data stored in RIPBuffer
- PDL: Data analyzed with PJLParser
- TIF: TIFF image data output by interpreter
2. Copy a key file for acquisition of an edited controller capture (getcapture) in the USB
memory with empty space.
3. Connect the USB memory to the USB port provided on the IC board (ICB).
4. About after waiting for 20 seconds, check to see if the access lamp of the USB memory
stops flashing.
:The underlined section is edited.
type=USB: Saved in the USB memory inserted.
switch=ON: Obtained switch=OFF: Not obtained
count=1 to ∞: Number of files obtained
(Overwritten with a number specified and deleted in the order
of the older files when out of memory.)
:The same as above
:The same as above
:The same as above
:The same as above
3
Production Support Department 2
CSES-TNI ID:
TNBT0900038EN*.
43/48
2009/08/07
BT-CSO