Alarm Control

■ Alarm Selection
To control alarm behaviors, you need to select a
desired alarm number.
1. Select a desired alarm number by pressing the
numeric buttons.
MON 1
0123 Unit:01
2. Press the ALARM/ALM SUSPEND button.
The current status of selected alarm will be dis-
played on the LCD.
MON Alarm00001 CAM
0123
Armed
Armed: The system is armed for alarm response.
Active: Alarm has been triggered and activated
assigned alarm response.
Ack: Alarm is acknowledged and an operator can
control the alarm action.
Reset: Activated alarm is reset, but the alarm
device is still active.
Disarm: The system is disarmed for alarm
response.
Clear: Auto arming is not set in the admin console.
3. To select the next alarm number, press the + but-
ton.
To select the previous alarm number, press the –
button.
■ Alarm Arming Control
CAM
00512
00512
To arm or disarm all alarms
Every time you press the ALARM/ALM SUSPEND but-
ton while holding down the SHIFT button, all alarms
will be armed or disarmed.
• To arm or disarm an alarm, activate Allow Disarm
1. Select a desired alarm. (Refer to Alarm Selection.)
2. Every time you press the ALARM/ALM SUSPEND
button, the selected alarm will be armed or dis-
armed. When an alarm is disarmed, the LCD dis-
play will become as follows.
MON Alarm00001 CAM
0123
Disarm
3. To exit the alarm mode, press the CLEAR button.
The LCD display will become as follows.
MON Alarm Exit CAM
0123 Unit:01
MON
0123 ALL Arm
MON
0123 ALLDisarm 00512
Note:
for the alarm. (Refer to the Admin Console User's
Guide for details.)