Configuration

Alarm Input/Output

Alarm input and alarm output ports are used for alarm action purposes, and although each
has a specific function, both are configured within this section. Although the system
controller operator must control the I/O ports by logical number, these ports are viewable
within MPU955 Admin Console by both ID and logical port numbers.
Each encoder supplies 8 ports – 4 are input ports, 4 are output ports. Because of this, 4
consecutive IDs must be configured with the same directional type - either input or output.
For example, if ID 1 is configured as an input port, then IDs 2-4 must be input ports as
well. Then, port 5 through port 8 must be configured as output ports.
Definition
1. Select the I/O Ports command from the Controller menu
Add, Edit, Delete, or Replicate alarm I/O port records as needed using the four icons at
the bottom of this window. Deleting a port will delete the entire bank that port is part of.
79