MON: Monitor number
-A-: Area number
CAM/DVR/SEQ:
<Example>
C6400001: Unit 64, Camera 1
R6400001: Unit 64, Recorder 1
T640010001P: Unit 64, Area 1, Tour Sequence
1 pause
G640010001P: Unit 64, Area 1, Group
Sequence 1 pause
DEV: Device Name
K: System controller number with normal user
operator.
S: System controller number with super user
operator.
ALM: Alarm
EVT: Timer event
USER: User ID
Note: Alarm USRID consists of alarm number
and alarm action number.
E.g. "ALM20" indicates alarm #2 and its
action #0.
PRI: User priority
4. To display the next page, press the + button.
To display the previous page, press the – button.
Note:
• To display the first page of table, press the + but-
ton while holding down the SHIFT button.
• To display the last page of table, press the – button
while holding down the SHIFT button.
• If the DVR is a network disk recorder, R6400001
indicates the camera number related to the record-
er.
• The PRI field indicates "–" when the priority is set
to "0".
• In case of global camera numbering method, the
camera number is just up to 7 digits number. And
also the tour sequence number is up to 4 digits
number. i.e. C1234567: Camera 1234567, T501P:
Tour Sequence 501 Puase.
• While the WV-ASM970 performs the synchronous
playback, the CAM/DVR/SEQ field displays previ-
ous status for dedicated monitors.
58
5. To exit the SYSTEM STATUS table, perform either
of the following.
• Select a camera. (Refer to p. 39 Camera
Selection.)
• Press the MON(ESC) button.
• Press the EXIT button.
Note:
• This feature is available in only WJ-SX650 or
WJ-SX850 because of OSD limitation.
■ Video Loss History Table
There are 100 video loss detection records stored in
chronological order in 10 pages of table.
1. Select a desired monitor. (Refer to p. 39 Monitor
Selection.)
2. Display "VL Hist" menu. (Refer to Step 1 and 2 of
p. 53 To Recall Menu Functions.)
VL Hist:
On
Off
3. Select a desired function by pressing one of the F1
to F3 buttons.
Available buttons and functions
F1: On
Opens the VIDEO LOSS HISTORY table.
F2: Off
Closes the VIDEO LOSS HISTORY table.
F3: Blk
Changes the monitor background between camera
images and black picture.
VIDEO LOSS HISTORY
CAM
STATE
TYPE
6401
OK
CAM: Logical camera number that is connected to
the system.
011
Blk
PG
DATE/TIME
C