Wiring Tables and Information

Wiring Tables and Information

Figure 4: Wiring table for detection zone

Wire Gauge
(AWG)
22
20
18
16
14
12
Note: Maximum loop resistance should not exceed 100 ohms.

Figure 5: Wiring table for bells and horns

Signal circuits are rated for 1.25 amperes each.
Total Signal
Load
18AWG
Amperes
ft.
0.06
2350
0.12
1180
0.30
470
0.60
235
0.90
156
1.20
118
Note: Maximum voltage drop should not exceed 1.8 volts.
8
Maximum Wiring Run to Last Device (ELR)
ft.
2990
4760
7560
12000
19000
30400
Maximum Wiring Run to Last Device (ELR)
16AWG
m
ft.
m
716
3750
1143
360
1850
567
143
750
229
71
375
114
47
250
76
36
185
56
m
910
1450
2300
3600
5800
9200
14AWG
12AWG
ft.
m
ft.
6000
1829
8500
3000
915
4250
1200
366
1900
600
183
850
400
122
570
300
91
425
Max Loop
Resistance
0hms
m
Ohms
2591
30
1296
15
579
6
259
3
174
2
129
1.5