Operation with door left open:
Operation with the door open can cause excess smoke. The appliance must not be operated with the appliance
door left open except as directed in the instructions.
Dampers left open:
Operation with the air controls or dampers open can cause excess smoke. The appliance must not be operated
with air controls or dampers left open except as directed in the instructions.
Periods of Prolonged Non-Use
If the stove is to be left unused for a prolonged period of time then it should be given a thorough clean to remove
ash and unburned fuel residues. To enable a good flow of air through the appliance to reduce condensation and
subsequent damage, leave the air controls fully open.
Extractor fan
There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit
smoke and fumes into the room.
Aerosol sprays
Do not use an aerosol spray on or near the stove when it is alight.
Use of operating tools
Always use the operating tools provided when handling parts likely to be hot when the stove is in use.
Chimney Fires
If the chimney is thoroughly and regularly swept, chimney fires should not occur. However, if a chimney fire does
occur turn off the stove immediately and isolate the mains electricity supply (if applicable), and tightly close the
doors of the stove. This should cause the chimney fire to go out. If the chimney fire does not go out when the
above action is taken then the fire brigade should be called immediately. Do not relight the stove until the
chimney and flueways have been cleaned and examined by a professional.
Permanent air vent
The stove requires a permanent and adequate air supply in order for it to operate safely and efficiently.
In accordance with current Building Regulations the installer may have fitted a permanent air supply vent into the
room in which the stove is installed to provide combustion air. This air vent should not under any circumstances
be shut off or sealed.
USER OPERATING INSTRUCTIONS - WOOD
Please read the important notices given above before referring to the main instruction book for detailed operating
instructions.
HETAS Ltd Approval
HETAS approval may be limited to specific fuel types as detailed in the main instruction manuals. Approval does
not cover the use of other fuels either alone or mixed with the recommended fuel, nor does it cover instructions
for the use of other fuels.
Recommended fuels
Stoves may be designed to burn dry seasoned wood logs and/or solid mineral fuel as indicated in the main stove
manuals.
Door operation
The door handle may become hot during operation, use the tool to open and close the doors, if appropriate.
Lighting of fire
Place some firelighters or paper and dry kindling wood on the grate and cover with a small amount of fuel. Set air
controls to maximum and set light to firelighters or paper. Close the doors and allow fire to burn until fuel is well
alight then load with more fuel and adjust air controls to the required level of heat output.
Before relighting the fire clean the firebed of ash and clinker and empty the ashpan.
6