Piazzetta ME 90/44 D Instructions For Installation, Use And Maintenance Manual

Piazzetta ME 90/44 D Instructions For Installation, Use And Maintenance Manual

Advertisement

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ME 90/44 D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Piazzetta ME 90/44 D

  • Page 2: Important Information

    In line with its policy of constant product improvement and renewal, the manufacturer may make changes without notice. This document is the property of Gruppo Piazzetta S.p.A.; no part of it may be disclosed to third parties without the written permission of Gruppo Piazzetta S.p.A.
  • Page 3: Table Of Contents

    5.10 Cleaning the fan (ONCE A YEAR) 5.11 Shutting down 5.12 Closing door system TROUBLESHOOTING Declaration of conformity for models ME 90/44 D - ME 90/44 S This booklet code H07022210 / DT2000371 rev. 04 - (01/2009) comprises 60 pages. H07022210 - DT2000371 - 04...
  • Page 4: General Rules

    1.0 GENERAL RULES DT2011180-00 Before proceeding with installation, choose the most suitable position for your fireplace according to the indications given in the paragraph “MINIMUM SAFETY DISTANCES” and to all the indications below. Fig. 1 COMIGNOLO CHIMNEY STACK CANNA FUMARIA FLUEWAY HOOD GRILLE GRIGLIA DI CAPPA...
  • Page 5: Single Chimney Or Flueway

    It is forbidden to pass other air ducts or service pipes inside the flue pipe, however large it is. If the flue pipe is an incorrect size or installed other than in compliance with the above instructions, Gruppo Piazzetta DT2030258-00 S.p.A. cannot be held liable for malfunctioning of the product, damage to property or injury to persons or animals.
  • Page 6: Chimney Stack

    DT2010025-01 1.3 CHIMNEY STACK - Fig. 7 / 11 Fig. 7 Fig. 8 The chimney stack must comply with the following requirements: - it must have an internal section and shape the same as the fl ue (A); - it must have a useful outlet section (B) of not less than twice that of the fl...
  • Page 7: Fresh Air Intake

    DT2010539-03 1.4 FRESH AIR INTAKE - Fig. 12 / 14 Fig. 12 To ensure trouble-free operation the stove/fi replace must have the necessary air available for combustion and this is provided through the fresh air intake. The fresh air intake must: - have a total free cross section at least equal to the size given in the paragraph “TECHNICAL DATA”;...
  • Page 8: Installation Enviroment

    DT2010033-02 1.5 INSTALLATION ENVIROMENT The appliance should be installed in a location which allows safe and convenient use as well as easy maintenance. If the product being installed requires an electrical socket, the room must also be provided with an earthed power supply in accordance with current regulations. The room where the appliance is to be installed must comply with the following requirements.
  • Page 9: Methods Of Heat Diffusion

    1.8 METHODS OF HEAT DIFFUSION Fig. 15 Diffusion with the Multifuoco System - Fig. 15 - 16 Ceiling An original Piazzetta system designed to distribute heat evenly throughout the environment, even for several rooms on different fl oors. The Multifuoco System ®...
  • Page 10: Suitable Heat Insulating Materials

    Irrespective of the type of ducting, it is compulsory to install a Fig. 18 hood grille in the upper part of the surround so that the heat may fl ow out from the internal hood into the room. See the “TECHNICAL DATA”...
  • Page 11: Minimum Safety Distances

    DT2011184-00 1.10 MINIMUM SAFETY DISTANCES - Fig 20 / 23 Walls FLAMMABLE WALLS: the fi replace may be installed near fl ammable walls Fig. 20 FLAMMABLE WALLS provided suitable protection consisting of insulating and non-combustible material is inserted. Lining wall in fire retardant To insulate the fi...
  • Page 12: Connection To The Flueway

    45°. Pipes and bends made by Gruppo Piazzetta S.p.A. are recommended for connection to the fl ueway, since they are sized to fi t the fl ue outlet of the appliance and are also in compliance with regulations and standards.
  • Page 13: Lining Wall

    fi replace. Furthermore, the surround must be made with non-fl ammable materials in compliance with regulations. For Gruppo Piazzetta S.p.A. surrounds, follow the instructions enclosed with the product. Testing and lighting for fi rst time.
  • Page 14: Electric Power Supply

    DT2010179-01 1.15 ELECTRIC POWER SUPPLY Make sure there is a power socket 230V 50Hz in the rear fi replace wall ready for installing the ventilation kit and a switch on the outside of the cladding to be able to cut off the power supply during maintenance or when the appliance is not being used. The installation must be earthed and fi...
  • Page 15: Technical Data And Specifications

    2.0 TECHNICAL DATA AND SPECIFICATIONS DT2010356-02 DT2010781-01 2.1 DESCRIPTION OF THE APPLIANCE The ME high amenity-value fi replaces are the ideal solution for those seeking unusual forms. The ample glazed area and a clean-cut linear hearth front with concealed handle are beyond compare for a clear view of the fi re. The manual/automatic smoke damper makes stoking operations easy.
  • Page 16: Accessories End Equipment

    If the rating plate is missing, has been removed or tampered with, any installation and maintenance operations are made diffi cult due to lack of product identifi cation. In the event of damage, please ask the Piazzetta after-sales service centre for a copy. Product name Fig.
  • Page 17: Technical Data

    DT2011358-02 2.5 TECHNICAL DATA U.M. ME 90/44 D - ME 90/44 S Rated heat output 13.0 Consumption at rated heat output kg/h Thermal effi ciency 76.5 CO content (with 13% O2) 0.13 Approved in accordance with standard EN 13229 Test report No.
  • Page 18: Dimensions Me 90/44 D - Me 90/44 S

    DT2031927-00 2.6 DIMENSIONS ME 90/44 D - ME 90/44 S Typical illustration on model ME 90/44 S Measurements in cm. H07022210 - DT2000371 - 04...
  • Page 19: Preparation For Installing

    3.0 PREPARATION FOR INSTALLING DT2011359-00 Carefully read all the information contained in the section “GENERAL RULES” Fig. 30 before installing the fi replace. - Unpack the fi replace. - Take the accessories out of the hearth and remove the elements that secured the fi...
  • Page 20: Use

    4.0 USE DT2011360-00 Certain basic facts can be all-important for best performance and getting the most out of your appliance. Please fi nd below some basic information intended to be of use with regard to the choice of fi rewood, the adjustment of the dampers and proper operation of the appliance. During operation, some parts of the appliance (door, handle, dampers, surround) can reach high temperatures.
  • Page 21: Smoke Damper Regulation

    SMOKE DAMPER POSITION LIGHTING OR STOKING-UP OF FIREPLACE FIREPLACE IN OPERATION AT NOMINAL POWER ME 90/44 D-S CLOSED OPEN Whenever the fireplace is stoked with wood, the smoke damper automatically goes to the open position upon opening the door. After stoking the fire the damper must be returned manually to the position of operation.
  • Page 22: Combustion Air Regulation

    + or – as required. DETAIL A OPEN CLOSED DT2031940-00 Regulation and quantity of material to be burned for rated power: ME 90/44 D - ME 90/44 S Material to be burned See “COMBUSTIBLE” paragraph Air damper position 3 mm OPEN Smoke damper position CLOSED See “TECHNICAL DATA”...
  • Page 23: Lighting

    ME 90/44 S or on the left side for the model ME 90/44 D. Take care not to slam the door shut as the glass could break.
  • Page 24: Night Time Operation At Minimum

    - close the air dampers (MINIMUM position); The fi re will go out due to lack of air. When the appliance has cooled down, fi nd the cause of the problem and if necessary call in specialised personnel (C.A.T. – Piazzetta After-Sales Service Centre).
  • Page 25: Maintenance

    5.0 MAINTENANCE DT2011361-00 Maintenance is to be considered compulsory for correct and effi cient stove operation. If maintenance is not carried out with the recommended frequency, stove performance could suffer. The manufacturer will not be responsible for stove deterioration or malfunction if due to poor maintenance. All maintenance work (cleaning, any replacements, etc.) must be carried out when the stove is shutdown and cold.
  • Page 26: Cleaning The Glass (Daily)

    4 mm thick pyroceram panel resistant to thermal shock up to 750°C. This can only be broken by heavy impact, such as banging the door too hard. In the event of breakage replace with original Gruppo Piazzetta S.p.A. parts only. DT2031962-00 DT2010063-00 5.6 CLEANING THE GRATE AND THE ASH TRAY (DAILY)
  • Page 27: Removing The Smoke Baffle Plate

    All cleaning and maintenance operations must be carried out after DISCONNECTION OF THE POWER. Pursuant to current regulations on the safety of electrical equipment, you must contact a Piazzetta After-Sales Service Centre or a qualified electrician for all and any work connected with installation, maintenance or servicing that involves access to electrical parts.
  • Page 28: Troubleshooting

    The manufacturer shall not be liable for any problems caused by lack of or inefficient maintenance or by failure to comply with the instructions in the product installation and operating guide. This instruction booklet contains all the useful information for installation, operation and maintenance. Only call the Gruppo Piazzetta S.p.A. service centre after having scrupulously followed all the instructions.
  • Page 29 (*) Pursuant to current regulations on the safety of electrical equipment, you must contact a Piazzetta After-Sales Service Centre or a qualified electrician for all and any work connected with installation, maintenance or servicing that involves access to electrical parts.
  • Page 30: Declaration Of Conformity For Models Me 90/44 D - Me 90/44 S

    H07022210 - DT2000371 - 04...
  • Page 31 H07022210 - DT2000371 - 04...
  • Page 32 N° matricola prodotto da comunicare al Centro Assistenza Tecnica del Gruppo Piazzetta in caso di richiesta assistenza. Product serial number, to be quoted when requesting service from the Gruppo Piazzetta After-Sales Service Centre. Via Montello, 22 31011 Casella d’Asolo (TV) - ITALY Tel.