Electrical system
- Insert the MASTER key, turn it to "ON" and keep
it in that position for 2 seconds (limit values: 1 ÷ 3
seconds).
- Alternately insert all the available black keys and
turn each one of them to "ON" for 2 seconds.
- Insert the MASTER key again and turn it to "ON"
for 2 seconds.
The maximum time to change keys is 10 seconds.
A maximum of 7 (Black) service keys can be pro-
grammed at one time.
Sequence and times must be strictly observed or
it will be necessary to repeat the procedure from
the start.
Once the control unit has been programmed, the
control unit is inseparably matched with the MAS-
TER key transponder.
This matching allows programming further service
keys in case of loss, replacement, etc. Each new
time new data is programmed the previously stor-
ed one is deleted.
If a service key setting is lost, it is essential to
carefully check the efficiency of the high voltage
system:
Shielded cap resistance ~ 5000 Ω.
In any case it is advisable to use resistive spark
plugs.

Diagnostic codes

The flash indicating the switching to "ON" can be followed by a phase of programmed failure warnings.
That is, the led is off for 2 seconds, and then diagnosis codes are transmitted with 0.5-second flashes.
After the failure code indication, a steadily on LED signals that ignition is disabled; see the table:

Diagnostic code - 2 flashes

When the 2-flash code is detected, carry out the following checks:
- Check if the failure continues after changing key (MASTER key included). If the failure persists with
any key, disconnect the aerial connector from the control unit and check the aerial for continuity with
the recommended tool.
If non-conforming values are measured, replace the aerial.