Wiring; Main Circuit - Mitsubishi Electric FR-F740-00023 Installation Manuallines

Fr-f700 series
Hide thumbs Also See for FR-F740-00023:
Table of Contents

Advertisement

3 WIRING

Source logic
Main circuit terminal
Control circuit terminal
3-phase AC
power supply
*2.To supply power to the control circuit
separately, remove the jumper
across R1/L11 and S1/L21.
Control input signals (No voltage input allowed)
Terminal functions
Forward rotation
vary with the input
terminal assignment.
(Pr. 178 to Pr. 189)
Reverse rotation
Start self-holding selection
Multi-speed selection
Second function selection
*3. AU terminal can be
used as PTC input
terminal.
Terminal 4 input selection
(Current input selection)
Selection of automatic restart after
instantaneous power failure
Contact input common (Sink*)
24VDC power supply/max. 100mA load current
Contact input common(Source*)
*(Common for external power supply transistor)
Frequency setting signal (Analog)
Frequency setting
potentiometer
1/2W, 1k
*5
*4.Terminal input specifications
can be changed by analog
input specifications switchover
(Pr. 73, Pr. 267) (initial settings
in frame). Set the voltage/cur-
rent input switch in the OFF
position to select voltage input
(0 to 5V/0 to 10V) and ON to
select current input (0 to
20mA). Terminal 2 and 10 can
be used as PTC input terminal.
(Pr. 561).
*5.It is recommended to use 2W,
Ω
1k
when the frequency set-
ting signal is changed fre-
quently.
CAUTION
To prevent a malfunction due to noise, keep the signal cables more than 10cm away from the power cables.
After wiring, wire offcuts must not be left in the inverter.
Wire offcuts can cause an alarm, failure or malfunction. Always keep the inverter clean.
When drilling mounting holes in a control box etc., take care not to allow chips and other foreign matter to enter the inverter.
Set the voltage/current input switch in the correct position. An incorrect setting may cause a fault, failure or malfunction.
4
*1.DC reactor
Remove the jumper across P1
and P/+ for the 01160 or less if a
DC reactor is connected. Be sure
to connect the DC reactor sup-
plied with the 01800 or more.
MCCB
MC
Jumper
*2
Earth
start
start
High speed
Middle speed
Low speed
Jog operation
Output stop
Reset
3
2
Ω
1
(+)
Auxiliary
(-)
input
Terminal 4
(+)
input
(-)
(Current
input)
Connector for
plug-in option
connection
*1
Earth
Jumper
Jumper
P1
P/+
PR
PX
*7
*7
R/L1
Inrush current
S/L2
limit circuit
T/L3
ON
Connector for
R1/L11
with/without internal
S1/L21
OFF
EMC filter

Main circuit

Control circuit
STF
STR
STOP
RH
RM
RL
JOG
RT
MRS
RES
*3
AU
AU
PTC
CS
SD
24V
PU
PC
connector
Voltage/current
*4
input switch
4 2
10E(+10V)
ON
10(+5V)
OFF
0 to 5VDC
2
0 to 10VDC
* 4
4 to 20mADC
5
Analog common
0 to ±10VDC
1
* 4
0 to ±5VDC
4 to 20mADC
4
0 to 5VDC
* 4
0 to 10VDC
Option connector 1
Option connector 2
Terminating
resistor
Brake resistor
*6.The CN8 connector (for
(Option)
MT-BU) is provided with the
Brake unit
01800 or more
(Option)
*7 Do not use PR and PX terminals.
Please do not remove the jumper con-
nected to terminal PR and PX.
N/-
CN8
*6
U
V
W
Earth
C1
Terminal functions
B1
vary with the output
Relay output 1
terminal assignment.
(Alarm output)
A1
(Pr. 195, Pr. 196)
C2
B2
Relay output 2
A2
Open collector output
RUN
Running
Terminal functions
SU
vary with the output
Up to frequency
terminal assignment.
(Pr. 190 to Pr. 194)
IPF
Instantaneous
power failure
OL
Overload
FU
Frequency detection
SE
Open collector output common
Sink/source common
(+)
CA
Analog current output
(0 to 20mADC)
(-)
(+)
AM
Analog signal output
(0 to 10VDC)
5
(-)
TXD+
TXD-
Data transmission
RXD+
RXD-
Data reception
SG
GND
5V
(Permissible load
VCC
current 100mA)
Motor
M
3~
Relay output
RS-485
terminals