Print Date
Art. no.
August
2004
158537-A
January
2006
158537-B
02/2013
akl
158537-C
For Maximum Safety
Mitsubishi transistorized inverters are not designed or manufactured to be used in equipment or systems in situations
that can affect or endanger human life.
When considering this product for operation in special applications such as machinery or systems used in passenger
transportation, medical, aerospace, atomic power, electric power, or submarine repeating applications, please contact
your nearest Mitsubishi sales representative.
Although this product was manufactured under conditions of strict quality control, you are strongly advised to install
safety devices to prevent serious accidents when it is used in facilities where breakdowns of the product are likely to
cause a serious accident.
Please do not use this product for loads other than three-phase induction motors.
Please check upon receiving of the inverter whether this instruction manual corresponds to the delivered inverter.
Compare the specifications on the capacity plate with the specifications given in this manual.
First edition
General
Extension of the capacity classes by the inverters FR-F740-02600 to 12120
Addition of the inverters FR-F746-00023 to 01160 with IP54 protection rating
New parameter 299
General
Additions:
Usage of a residual current device
Voltage/current input switch
Option connector 2
Instructions for wiring of the main circuit of the FR-F740-05470 or more
Failsafe of the system which uses the inverter
Parameter
New setting values:
list
Pr. 29, Pr. 30 , Pr. 52, Pr. 54, Pr. 59, Pr. 128, Pr. 158, Pr. 167,
Pr. 178 to Pr. 189, Pr. 190 to Pr. 196, Pr. 261, Pr. 331, Pr. 332, Pr. 495,
Pr. 549, Pr. 573
New parameters:
Pr. 147, Pr. 296, Pr. 297, Pr. 390, Pr. 414, Pr. 415, Pr. 498, Pr. 502,
Pr. 505 to Pr. 515, Pr. 522, Pr. 539, Pr. 553, Pr. 554, Pr. 561, Pr. 653,
Pr. 654, Pr. 665, Pr. 726 to Pr. 729, Pr. 753 to Pr. 769, Pr. 774 to Pr. 779,
Pr. 799, Pr. 826 to Pr. 865, Pr. 870, Pr. 986, Pr. 997, Pr. 999, C42 (Pr. 934),
C43 (Pr. 934), C44 (Pr. 935), C45 (Pr. 935), PR.CH, AUTO
Partial modification:
Pr. 153 setting range „0 to 10 s"
Trouble-
Protective functions (E---, LOCD, E.OP2, E.2, E.5, E.PID, E.PCH, E.LCI)
shooting
Resetting the inverter
Appendix
Additions:
Breaker selection when using the inverter as UL or cUL listed product
Electronic thermal relay function operation characteristic
Partial modification:
Appendix 1 Instructions for compliance with the EU Directives