Mitsubishi Electric FR-F740-00023 Installation Manuallines page 24

Fr-f700 series
Hide thumbs Also See for FR-F740-00023:
Table of Contents

Advertisement

PARAMETER
Parameter Name
Power-failure
264
deceleration time 1
Power-failure
265
deceleration time 2
Power failure
deceleration time
266
switchover
frequency
Terminal 4 input
267
selection
Monitor decimal
268
digits selection
Parameter for manufacturer setting.
269
Do not make setting.
296
Password lock level
Password lock/
297
unlock
Rotation direction
299
detection selection
at restarting
RS-485
331
communication
station
RS-485
332
communication
speed
RS-485
333
communication stop
bit length
RS-485
communication
334
parity check
selection
RS-485
335
communication
number of retries
RS-485
336
communication
check time interval
RS-485
337
communication
waiting time setting
Communication
338
operation command
source
Communication
339
speed command
source
Communication
340
startup mode
selection
RS-485
341
communication
CR/LF selection
Communication
342
EEPROM write
selection
Communication error
343
count
% setting reference
390
frequency
*1
The setting depends on capacities. (01160 or less/01800 or more)
18
Initial
Setting Range
Value
0 to 3600/ 360s
5s
0 to 3600/ 360s,
9999
9999
0 to 400Hz
50Hz
0, 1, 2
0
0, 1, 9999
9999
0 to 6, 99, 100 to
9999
106, 199, 9999
(0 to 5),
1000 to 9998,
9999
9999
0, 1, 9999
9999
0 to 31
(0 to 127 or
0
0 to 247)
3, 6, 12, 24,
48, 96, 192, 384
96
(96, 192, 384,
768)
0, 1, 10, 11
1
0, 1, 2
2
0 to 10, 9999
1
0 to 999.8s,
9999
0s
0 to 150ms,
9999
9999
0, 1
0
0, 1, 2
0
0, 1, 2, 10, 12
0
0, 1, 2
1
0, 1
0
0
1 to 400Hz
50Hz
Parameter Name
PLC function
414
operation selection
Inverter operation
415
lock mode setting
Remote output
495
selection
496
Remote output data 1
497
Remote output data 2
PLC function flash
498
memory clear
Stop mode selection
502
at communication
error
503
Maintenance timer
Maintenance timer
504
alarm output set time
Speed setting
505
reference
506
Parameter 1 to 10 for
to
user
515
Output stop
522
frequency
Modbus-RTU
539
communication
check time interval
549
Protocol selection
NET mode operation
550
command source
selection
PU mode operation
551
command source
selection
553
PID deviation limit
PID signal operation
554
selection
555
Current average time
Data output mask
556
time
Current average
value monitor signal
557
output reference
current
PTC thermistor
561
protection level
Energization time
563
carrying-over times
Operating time
564
carrying-over times
Multiple rating
570
setting
Holding time at a
571
start
4mA Input check
573
selection
Output interruption
575
detection time
Output interruption
576
detection level
Output interruption
577
release level
Initial
Setting Range
Value
0/1
0
0/1
0
0, 1, 10, 11
0
0 to 4095
0
0 to 4095
0
0 to 9999
0
0 to 3
0
0 (1 to 9998)
0
0 to 9998, 9999
9999
1 to 120Hz
50Hz
0 to 65535
0
0 to 400Hz,
9999
9999
0 to 999.8s,
9999
9999
0, 1, 2
0
0, 1, 9999
9999
1, 2
2
0 to 100.0%,
9999
9999
0 to 3, 10 to 13
0
0.1 to 1.0s
1s
0.0 to 20.0s
0s
0 to 500A/
Rated
1
0 to 3600A *
inverter
current
Ω
0.5 to 30k
,
9999
9999
(0 to 65535)
0
(0 to 65535)
0
0, 1
0
0.0 to 10.0s,
9999
9999
1, 2, 3, 4, 9999
9999
0 to 3600s, 9999
1s
0 to 400Hz
0Hz
900 to 1100%
1000%