PARAMETER
Parameter Name
Input phase failure
872
protection selection
Regeneration
882
avoidance operation
selection
Regeneration
883
avoidance operation
level
Regeneration
avoidance at
884
deceleration
detection sensitivity
Regeneration
avoidance
885
compensation
frequency limit value
Regeneration
886
avoidance voltage
gain
888
Free parameter 1
889
Free parameter 2
Cumulative power
891
monitor digit shifted
times
892
Load factor
Energy saving
893
monitor reference
(motor capacity)
Control selection
during commercial
894
power-supply
operation
Power saving rate
895
reference value
896
Power unit cost
Power saving
897
monitor average time
Power saving
898
cumulative monitor
clear
Operation time rate
899
(estimated value)
C0
CA terminal
*2
(900)
calibration
C1
AM terminal
*2
(901)
calibration
C2
Terminal 2 frequency
setting bias
*2
(902)
frequency
C3
Terminal 2 frequency
*2
(902)
setting bias
125
Terminal 2 frequency
setting gain
*2
(903)
frequency
C4
Terminal 2 frequency
*2
(903)
setting gain
C5
Terminal 4 frequency
setting bias
*2
(904)
frequency
*1
The setting depends on capacities. (01160 or less/01800 or more)
*2
The parameter number in parentheses is the one for use with the parameter unit (FR-PU04/FR-PU07).
20
Initial
Setting Range
Value
0, 1
0
0, 1, 2
0
300 to 800V
760V DC/
785V DC *1
0 to 5
0
0 to 30Hz,
9999
6Hz
0 to 200%
100%
0 to 9999
9999
0 to 9999
9999
0 to 4, 9999
9999
30 to 150%
100%
0.1 to 55kW/
LD/SLD
1
value of
0 to 3600kW *
applied
motor
capacity
0, 1, 2, 3
0
0, 1, 9999
9999
0 to 500, 9999
9999
0, 1 to 1000h,
9999
9999
0, 1, 10, 9999
9999
0 to 100%,
9999
9999
0 to 400Hz
0Hz
0 to 300%
0%
0 to 400Hz
50Hz
0 to 300%
100%
0 to 400Hz
0Hz
Parameter Name
C6
Terminal 4 frequency
*2
(904)
setting bias
126
Terminal 4 frequency
setting gain
*2
(905)
frequency
C7
Terminal 4 frequency
*2
(905)
setting gain
C8
Current output bias
*2
(930)
signal
C9
Current output bias
*2
(930)
current
C10
Current output gain
*2
(931)
signal
C11
Current output gain
*2
(931)
current
C42
PID display bias
*2
(934)
coefficient
C43
PID display bias
*2
(934)
analog value
C44
PID display gain
*2
(935)
coefficient
C45
PID display gain
*2
(935)
analog value
Terminal 10
986
calibration for PTC
thermistor
Parameter copy
989
alarm release
990
PU buzzer control
PU contrast
991
adjustment
997
Fault initiation
Automatic parameter
999
setting
Pr.CL
Parameter clear
ALLC
All parameter clear
Er.CL
Alarm history clear
PCPY
Parameter copy
Initial value change
PR.CH
list
Automatic parameter
AUTO
setting
Initial
Setting Range
Value
0 to 300%
20%
0 to 400Hz
50Hz
0 to 300%
100%
0 to 100%
0%
0 to 100%
0%
0 to 100%
100%
0 to 100%
100%
0 to 500.00,
9999
9999
0 to 300.0%
20%
0 to 500.00,
9999
9999
0 to 300.0%
100%
4 to 6V, 8888,
9999
5.00V
1
10/100 *
1
10/100 *
0, 1
1
0 to 63
58
16 to 18, 32 to
34, 48, 49, 64,
80 to 82, 96,
112, 128, 129,
144, 145, 160,
161, 162, 164 to
9999
168, 176 to 179,
192 to 194, 196
to 199, 228, 229,
230, 241, 242,
245 to 247, 253,
9999
1, 2, 10, 11, 20,
9999
21, 30, 31, 9999
0, 1
0
0, 1
0
0, 1
0
0, 1, 2, 3
0