Mitsubishi GOT1000 GT15 User Manual page 127

Graphic operation terminal
Hide thumbs Also See for GOT1000 GT15:
Table of Contents

Advertisement

(d) For GT156
The control panel side installation unit cannot be installed within 25mm (0.98inch) from the
GOT.
When the other extension units are used, the control panel side installation unit cannot be
installed in the areas shown in the following figure.
Hole for installing
GOT
(View from the
rear side)
80
40
(3.15) (1.57)
Prohibited area for installation
with an extension unit
Extension unit
Bus connection unit
Serial communication unit
Ethernet communication unit
MELSECNET/H communication unit
MELSECNET/10 communication
unit
CC-Link IE Controller Network
communication unit
CC-Link IE Field Network
communication unit
CC-Link communication unit
Printer unit
Model
GT15-ABUS, GT15-ABUS2,
GT15-75ABUS2L, GT15-75ABUSL
GT15-QBUS, GT15-QBUS2,
GT15-75QBUSL, GT15-75QBUS2L
GT15-RS2-9P, GT15-RS4-9S
GT15-RS4-TE
GT15-J71E71-100
GT15-J71LP23-25
GT15-J71BR13
GT15-75J71LP23-Z
GT15-75J71BR13-Z
GT15-J71GP23-SX
GT15-J71GF13-T2
GT15-J61BT13, GT15-75J61BT13-Z
GT15-PRN
6.3 Mounting Position
1
X
2
(Unit: mm(inch))
28.5(1.12)
50(1.97)
27.5(1.08)
3
*
-
49(1.93)
43(1.69)
91(3.58)
*
-
4
35(1.38)
21(0.83)
35(1.38)
*
-
5
6
7
8
6
- 9