After the listed HT chimney has been installed, but before the chimney cap is placed, the BCC top mounted
Spider Damper must be installed. The Spider Damper is placed in the top section of the listed HT chimney.
The Spider Drop-in Damper (25-1) (Part #21) installs typically like other top mounted dampers. The bottom
hook-up is also typical. Attach the ring on the 28' stainless cable (Part #22) to the underside ring of the Spider
Damper. (25-2) The installer must go to the roof and place the Spider Drop-in Damper inside the top section of
the type HT chimney until handles of damper don't go any further down. (25-3, 25-4) Unroll cable, dropping it
all the way down the flue until cable reaches the firebox. The important installation step to be observed is as fol-
lows: check for tightness in between flue walls and outside damper. Any air clearance should be sealed with flat
gasket or silicone caulk. (25-5) Check damper plate to be sure it moves freely. Because blade is counterweight,
damper should always be in the opening position.