Pour in perlite beads insulation to absolute top of unit. Tap or
vibrate shell enclosure to settle perlite. Retap as necessary,
ensuring there are no voids. (23-1)
Continue filling and packing until the top of shell is covered.
Replace the BCC top lid enclosure and reinstall sheet metal
screws to hold it in place. (23-2)
Place stainless steel slip connector (Part #20) into 8" (204mm)
refractory Turbo opening. Place first section of HT listed chim-
ney section into slip connector. (23-3) Fill any loose space
around HT chimney with extra left over Hollow Wool ceramic
fiber insulation.
Perlite
23
Bellfires® BCC
8" Diameter
Listed Type HT
UL1482 or
ULC S627
Chimney
Slip
connector