Bcc 28 Ht Chimneys - Bellfires BCC-28 Tall Installation Manual

Close clearance models
Table of Contents

Advertisement

Bellfires® BCC
Install a Listed HT UL1482 or ULC S627 Chimney
Depending on the existing framing limitations of the house either a straight or offset chimney will be installed.
Bellfires® BCC fireplaces can be installed with any 8" Diameter Listed Type HT UL1482 or ULC S627 Chimney.
Review the chimney manufacturer's installation instructions for details and minimum requirements. Be sure to
follow all instructions for the framing of openings in ceilings and floors, to provide firestopping in joist areas,
and to install all proper firestop-spacer assemblies.
WARNING:
WHEN INSTALLING THIS FIREPLACE WITH A CHASE ABOVE THE ROOF
REFER TO THE CHIMNEY MANUFACTURER'S INSTRUCTIONS FOR CHASE CONSTRUCTION.
Maximum chimney height from the top of the Bellfires® BCC fireplace to the top of the chimney
should not exceed 40 feet when supported solely by the fireplace, or 90 feet when resupported
at or above 40 feet according to the chimney manufacturer's resupport specifications.
It is the installer 's responsibility to provide the owner with a safe, fully operational venting system that meets
state or provincial and local codes. The majority of solid-fuel related fires are caused by chimney fires.