Saving
Save Active Settings except Factory for Power-on
• Initializes serial configuration commands in
active memory and resets counters to zero.
• Saves all active settings except factory settings
to NOVRAM for power-on.
By Software Command
Send
<Z>
command to the scanner.
By ESP
Right-click
in the configuration window and select
Save to Scanner, Send and
Note: Allow a
1
second delay after sending the <Z> command before resuming.
Save Active Settings including Factory for Power-on
• Initializes serial configuration commands in
active memory and resets counters to zero.
• Saves all active settings including factory set-
tings to NOVRAM for power-on (factory settings
include but are not limited to Focus, Gain, Track-
ing, and Scan Speed).
By Serial Command
Send
<Zp>
command to the scanner.
By ESP
Right-click
in the configuration window and select
Including
Factory.
MS-820 Industrial Bar Code Scanner User's Manual
Defaulting/Saving/Initializing
<
>
Z
User-Saved
NOVRAM
Save.
<
>
Zp
User-Saved
NOVRAM
Advanced, Send and Save,
Initialize
Active
Memory
Flash
Defaults
Initialize
Active Memory
and Factory Settings
Flash
Defaults