Read Rate
Read Rate
By ESP
You can access Read Rate from the Utilities menu.
To start or end a read rate test, right-click
To change from percent read rate to decodes per second, first end the read rate by
selecting Stop, then right-click select Decodes/Sec.
By Serial Command
Enter Single Label Decodes/Second Test
Sending
<C>
instructs the scanner to transmit the decodes per second and label data
(if any). The decode rate can vary dramatically due to the angle and location of the
label in relation to the scan line. This test is very useful in aligning and positioning the
scanning device during installation.
Enter Single Label Percent Test
Sending
<Cp>
instructs the scanner to transmit the percentage of decodes and any
scanned label data.
Enter Multilabel Percent Test
Sending
<Cm>
instructs the scanner to transmit the percentage of scans decoded and
label data (if any) for multiple labels.
Enter Multilabel Decode Rate Test
Sending
<Cs>
instructs the scanner to transmit the decode rate and label data (if
any) for multiple labels.
11-10
MS-820 Industrial Bar Code Scanner User's Manual
Read Rate
and select
Start
or Stop.