Steel City 45960C User Manual page 25

10" granite cabinet saw
Table of Contents

Advertisement

1. To align the blade parallel to the miter slot, first
loosen two hex soc head screws (A) under the front
side of the table saw. This is the same side as the
raise/lower handwheel (B). SEE FIG. 29
Fig.29
2. Remove the End cap on the rear side of the table
saw, Loosen two hex soc head screws (C). SEE FIG.30
Fig.30
3. The saw table is now loose and can be repositioned
until the blade is parallel to the miter slot. Repeat
"CHECKING BLADE ALIGNMENT."
steps in
4. When blade is parallel to miter slot, tighten all four
hex soc head screws.
5. Recheck blade alignment.
6. Tilt the blade to 45 degrees, and rotate the saw
blade by hand. Make sure the blade does not
contact the table insert.
A
C
BEVEL ARROW ADJUSTMENT
1. Make certain that the blade is at 90-degrees to the
Table surface with a combination square.
Fig. 31
B
2. Check that the bevel arrow is pointing to the zero
degree mark on the bevel scale located on the front
of the cabinet.
3. To adjust arrow, loosen the Philips head screw (A),
and reposition the bevel arrow and tighten screw.
25
A
SEE FIG 31.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

45975g45970g45965c369633596435971 ... Show all

Table of Contents