6. Lamp & lamp house
Image 6-17
11. Reinstall the side cover of the lamp house as illustrated.
Note: Please ensure that the thumb screws turning wires are flash with the cover or interference will occur while inserting the
lamp house into the projector.
Image 6-18
C
AUTION
after each installation of an xenon bulb lamp inside the lamp house. Neglecting this update will result in poor
performance and short life time of the xenon bulb lamp. See procedure "Resetting the lamp parameters", page
59.
A realignment of the xenon bulb lamp in its reflector is required after the installation of the xenon bulb lamp
in the lamp house. See procedure "Realignment of the lamp in its reflector", page 60.
56
A
:
The "LAMP INFO" parameters which are stored on a chip inside the lamp house MUST be updated
2,5 Nm
R59770091 DP-1500 06/01/2009