Barco DP-1500 Installation Manual page 57

Projectors
Hide thumbs Also See for DP-1500:
Table of Contents

Advertisement

Image 6-10
3. Install the lamp cathode adaptor (A) upon the xenon bulb lamp (L) as illustrated. Use torque 2,5 Nm to fasten the fixation screw
(S) of the adapter. Use for that a torque wrench with a 5 mm Allen socket. Make sure that there is full contact between the
cathode adapter and the lamp base.
Note: The cathode lamp adaptor is delivered in a separate bag with the projector. In case of a lamp replacement you have to
reuse the adaptor from the xenon bulb lamp which you want to replace.
S
Image 6-11
4. Install the anode wire lug (L) upon the anode socket (S). Hold fast the nut N1 with an open-end wrench while fastening the nut N2
with a torque of 9 Nm using a torque wrench. Ensure that at both sides of the wire lug L a plane washer (W1 & W2) is present.
Note: The anode socket is located just below the UV blocker and can easily be removed from the lamp house. In case of a lamp
replacement you have to reuse the anode socket which is connected to the xenon bulb lamp which you want to replace.
R59770091 DP-1500 06/01/2009
L
A
6. Lamp & lamp house
2,5 Nm
53