INSTALLING EXTERIOR CABLES AND CONNECTING TO GROUND BLOCK

PARTS NEEDED
• Type RG-6 coaxial cable
• 14 AWG copper/ 8 AWG ground wire
• F-type ground block and screws
INSTALLATION PROCEDURE
This section describes routing and installing the coaxial cable
between the low-noise block (LNB) on the dish and the ground
block. You may have to bury the coaxial cable, particularly if
you use a metal pole install. Use only quality burial specified
cables. When normal coaxial cable is buried, its useful life is
shortened. The outer cover decays in the soil, absorbs moisture,
and corrodes. Cables suitable for burial use a special outer
cover that resists breakdown. Some of these cables use flooded
gel and treated shields. This coating resists corrosion if water
gets into the cable. By using quality burial specified cables,
you avoid problems in the future.
An important goal of your cable installation is to protect the
cable from physical damage and moisture penetration. To pro-
tect the cable from physical damage, secure it to walls or other
stable surfaces with cable ties. This prevents the cable from
sagging and being damaged by people stepping on it or running
over it with yard equipment. Prevent moisture penetration by
using weatherproof connectors, and by sealing any connection
that is exposed to the elements. Drip loops provide a connec-
tion with additional protection by preventing moisture from
traveling down the cable and entering the connection.
Remember that the grounding wire must be 14 AWG copper if
it passes within 12 inches of masonry or soil.
Note: if you do not use RG6 quad shielded cable (CommScope 5781
or equivalent) you must run a ground wire from the mast base plate to
the ground block (see page 31) and install it and the ground block
ground wire onto a split bolt and clamp nut.
CAUTION
• Verify before you drill that there are no pipes in the wall
near where you will be drilling.
• Damaging pipes may cause property damage.
WARNING
• Verify before you drill that there are no electrical wires
in the wall near where you will be drilling.
• You may be killed or seriously injured if you contact wir-
ing while drilling.
1. Determine where you will install the ground block. It must
be near where the coaxial cable enters the building. Plan a
short and straight path for the ground wire from the ground
block to the grounding scheme.
2. Secure the ground block to a stable mounting surface with
two screws (see Figure 37).
• Cable ties or U-shaped tacks
• If needed, split bolt and clamp
nut
3. Connect one end of the 14 AWG copper/ 8AWG aluminum
4. Connect the other end of the ground wire to the grounding
5. Select a length of cable that can be routed easily between
6. Connect the coaxial cable to the ground block (see
7. Connect the interior cable (coming out of the access hole in
8. Tighten the cable connections with a 7/16-inch wrench.
TOOLS NEEDED
• Flat-blade screwdriver
• Phillips-head screwdriver
• 7/16-inch open-end wrench
ground wire to the ground terminal of the ground block.
scheme. If necessary, secure the ground wire with cable ties
or insulated U-shaped tacks.
the LNB on the feed assembly and the ground block.
Figure 38). Form a drip loop and secure the cable with cable
ties. A drip loop 2 or 3 inches in diameter is large enough;
the diameter can be no more than 14 inches.
the wall) to the opposite side of the ground block (see
Figure 37). Form a drip loop and secure with cable ties.
Into building
Figure 37
Figure 38
• Hammer
• 14/8 AWG wire cutters
To antenna
Sealant
Ground wire
G-22680
06/08/01
29