Riello Dialog Plus DLP series User Manual

Riello Dialog Plus DLP series User Manual

700-3000 va

Advertisement

UNINTERRUPTIBLE POWER SUPPLY
- ON LINE -
700 VA ÷ 3000 VA
User's manual

Advertisement

Table of Contents
loading

Summary of Contents for Riello Dialog Plus DLP series

  • Page 1 UNINTERRUPTIBLE POWER SUPPLY - ON LINE - 700 VA ÷ 3000 VA User’s manual...
  • Page 3 SAFETY This part of the manual contains precautions that must absolutely be followed as they relate to SAFETY. Installation Connect the UPS system only to an earthed shockproof socket outlet. The building wiring socket outlet (shockproof socket outlet) must be easily accessible and close to the UPS system.
  • Page 5 USER’S MANUAL...
  • Page 6 NTRODUCTION Thanks you for choosing our product. Our manufacturer are renowned specialists in the development and production of uninterruptible power supplies (UPS). The UPS in this range are high quality products, designed and built with care in order to give you the best performance.
  • Page 7: Table Of Contents

    ONTENTS RESENTATION IEW OF THE Front Views Rear Views IEW OF LED INDICATOR PANEL NSTALLATION AND PENING THE PACKAGING AND CHECKING THE CONTENTS ONNECTIONS AND SWITCHING ON FOR THE FIRST TIME Connection to the Net/Tel protection device WITCHING ON FROM MAINS POWER WITCHING ON FROM BATTERY WITCHING OFF THE ED INDICATOR PANEL...
  • Page 8: Presentation

    RESENTATION The new Dialog Plus family of UPS has been designed to offer versatility and reliability. They use ON LINE technology, which means that the AC power for the load is converted to DC and then back to AC again to ensure a perfectly sinusoidal output, the frequency and voltage of which are established by microprocessor digital control and are independent of the input power source.
  • Page 9: View Of The Ups

    RESENTATION IEW OF THE Front Views Models: 700-1000-1500VA Models: 2000-3000VA 1. LED indicator panel 2. ON button 3. OFF button...
  • Page 10: Rear Views

    RESENTATION Rear Views Dialog Plus 70 Dialog Plus 100 / 100 ER / 150 Dialog Plus 200...
  • Page 11 RESENTATION Dialog Plus 200 ER Dialog Plus 300 / 300 ER 1. RS232 serial communication port 6. Output sockets 2. Cooling fans 7. Communication expansion slot 3. Telephone/modem protection 8. Battery expansion connector 4. Input thermal protection 9. 16A output socket 5.
  • Page 12: View Of Led Indicator Panel

    RESENTATION IEW OF LED INDICATOR PANEL Load level indicator Battery level indicator Mains mode indicator Battery mode indicator / Battery low indicator Battery failure indicator Load powered by bypass indicator “Fault/Stand-by” indicator...
  • Page 13: Installation And Use

    NSTALLATION AND PENING THE PACKAGING AND CHECKING THE CONTENTS The first thing to do after opening the packaging is to check the contents The packaging should contain the following: RS232 serial cable IEC 10A(or 16A) Power cord IEC 16A Power cord set (only for model 3000VA) 2 IEC 10A connection cables User manual + CD-ROM with software...
  • Page 14: Connections And Switching On For The First Time

    NSTALLATION AND USE This chapter describes the operations to be carried out to prepare the UPS. WARNING: the instructions below should be followed scrupulously for your personal safety and that of the product. BEFORE CARRYING OUT THE FOLLOWING SEQUENCE OF OPERATIONS, MAKE SURE THAT THE UPS IS COMPLETELY SWITCHED OFF AND IS NOT CONNECTED TO THE MAINS OR TO ANY LOAD.
  • Page 15: Switching On From Battery

    NSTALLATION AND WITCHING ON FROM BATTERY When mains power is not available, press the ON button for about 1 second (until a beep sounds and then release it). All the icons on the indicator panel light up for 1 second and a beep sounds. A test is run on the batter voltage and, if all is normal, only the “Battery mode”, load level and battery level indicators stay on accompanied by an intermittent beep.
  • Page 16: Led Indicator Panel

    NSTALLATION AND ED INDICATOR PANEL This chapter gives a detailed description of all LED indicator panel. ICON STATUS DESCRIPTION Red / Steady Indicates an fault Red / The UPS is in stand-by mode Flashing Green / Steady The UPS is operating on mains power The UPS is operating off the bypass Green / Flashing The voltage input is out of the accepted range...
  • Page 17: Overloads On The Ups

    NSTALLATION AND Table 2 Battery LED bar Battery level 0%~20% ● 20%~40% ● ● 40%~60% ● ● ● 60%~80% ● ● ● ● 80%~100% ● ● ● ● ● Table 3 Battery LED bar Input Voltage 190V~200V ● 200V~230V ● ●...
  • Page 18: Communication Ports

    NSTALLATION AND After switching over to the bypass due to overloading, the UPS powers the loads off mains power and a continuous alarm will sound. By reducing the load within the 102% threshold, the UPS returns to normal operating mode. When the overload level is too high, the input thermal protection is activated and the UPS will be completely shutdown.
  • Page 19: Communication Slot

    NSTALLATION AND Communication Slot All UPS come with an expansion slot for optional communication boards so that the unit is compatible with the main communication standards. Some examples: • Serial port duplexer • Ethernet network agent with TCP/IP, HTTP and SNMP protocols •...
  • Page 20: Ups Configuration

    NSTALLATION AND UPS C ONFIGURATION The following table lists all the possible configurations available so as to best adapt the UPS to user requirements. The configuration may be modified only by using the configuration software provided. FUNCTION DESCRIPTION PREDEFINED POSSIBLE CONFIGURATIONS •...
  • Page 21: Alarms And Indicators

    LARMS AND NDICATORS The following table describes the light and audio indicators that appear/sound during normal UPS operation. Load level Battery level Battery Failure/ Mains Battery Audio UPS Status pass failure Fault Alarm ♦ Standby ♦ ● Bypass Load level Battery level ●...
  • Page 22: A Larms And I Ndicators

    LARMS AND INDICATORS The following table describes the light and audio signals that appear/sound to indicate a fault. Load level Battery level Battery Failure/ Mains Battery Bypass Audio UPS Status failure Fault Alarm 1 2 3 4 5 1 2 beeps Alarm phase ●...
  • Page 23: Problem Solving

    ROBLEM SOLVING Very often incorrect UPS operation is not caused by a fault but by common problems, difficulties or carelessness. The table below gives some useful information to help the user solve the most frequent problems. PROBLEM POSSIBLE CAUSE SOLUTION THE POWER CABLE IS NOT Check that the power cable is connected correctly.
  • Page 24: Technical Specifications

    ECHNICAL PECIFICATIONS MODELS Dialog Plus 70 Dialog Plus 100 Dialog Plus 100 ER INPUT Nominal voltage (±1.5%) [Vac] 220 / 230 / 240 Transfer Voltage Range - low line transfer [load %] Based on load percentage [Vac] 100-80% =160 ± 5 80-70% = 140 ±...
  • Page 25 ECHNICAL SPECIFICATIONS MODELS Dialog Plus 150 Dialog Plus 200 Dialog Plus 200 ER INPUT Nominal Voltage (±1.5%) [Vac] 220 / 230 / 240 Transfer Voltage Range -Low line transfer [load %] Based on load percentage [Vac] 100-80% =160 ± 5 80-70% = 140 ±...
  • Page 26 ECHNICAL PECIFICATIONS MODELS Dialog Plus 300 Dialog Plus 300 ER INPUT Nominal voltage (±1.5%) [Vac] 220 / 230 / 240 Transfer Voltage Range -Low line transfer [load %] Based on load percentage [Vac] 100-80% =160 ± 5 80-70% = 140 ± 5 70-60%= 120 ±...
  • Page 27 ECHNICAL SPECIFICATIONS at nominal load, minimum voltage of 164 Vac, battery charging at nominal load, nominal voltage of 230Vac, battery charging Second appendix M5 of the EN50091-1-1 specifications Mains/Battery at load: 0% -100% at Mains / battery / mains at resistive load: 0% / 100% / 0% If the mains frequency falls within ±...
  • Page 28 UPS MANUFACTURING s.r.l. I – 37048 S.Pietro di Legnago (VR) Italy – Viale Europa, 7 – ZAI Tel. +39 0442 635811 – Fax +39 0442 629098 www.riello-ups.com - riello@riello-ups.com 0MNUOC1RUA_GB (614-06498-00)

Table of Contents