Check Motor Rotation - Carrier 19XRV Start-Up, Operation And Maintenance Instructions Manual

Hermetic centrifugal liquid chillers with pic iii controls 50/60 hz hfc-134a
Table of Contents

Advertisement

Table 14 — Refrigerant (HFC-134a) Charge
REFRIGERANT
COOLER
CHARGE
CODE
lb
kg
20
345
156
21
385
175
22
435
197
30
350
159
31
420
191
32
490
222
35
400
181
36
480
218
37
550
249
40
560
254
41
630
286
42
690
313
45
640
290
46
720
327
47
790
358
50
750
340
51
840
381
52
900
408
55
870
395
56
940
426
57
980
445
60
940
426
61
980
445
62
1020
463
65
1020
463
66
1060
481
67
1090
494
70
1220
553
71
1340
608
72
1440
653
75
1365
619
76
1505
683
77
1625
737
80
1500
680
81
1620
735
82
1730
785
85
1690
767
86
1820
826
87
1940
880
INITIAL START-UP
IMPORTANT: The Reliance VFD warranty will be void if
the VFD is not started by a technician who has completed
Reliance LiquiFlo™ Tier 1 Training and whose name is
registered with Reliance.
Before starting the chiller, verify:
Preparation —
1. Power is on to the VFD, oil pump relay, oil heater relay,
and the chiller control panel.
2. Cooling tower water is at proper level and at-or-below
design entering temperature.
3. Chiller is charged with refrigerant and all refrigerant and
oil valves are in their proper operating positions.
4. Oil is at the proper level in the reservoir sight glasses.
5. Oil reservoir temperature is above 140 F (60 C) or above
refrigerant temperature plus 50° F (28° C).
6. Valves in the evaporator and condenser water circuits are
open.
NOTE: If the pumps are not automatic, ensure water is
circulating properly.
Do not permit water or brine that is warmer than 110 F
(43 C) to flow through the cooler or condenser. Refrigerant
overpressure may discharge through the relief valves and
result in the loss of refrigerant charge, damaging the chiller.
7. Access the CONTROL TEST screen. Scroll down on the
TERMINATE LOCKOUT option. Press the SELECT (to
enable the chiller to start) and answer YES to reset unit to
operating mode. The chiller is locked out at the factory in
order to prevent accidental start-up.
REFRIGERANT
CONDENSER
CHARGE
CODE
lb
kg
20
225
102
21
225
102
22
225
102
30
260
118
31
260
118
32
260
118
35
310
141
36
310
141
37
310
141
40
280
127
41
280
127
42
280
127
45
330
150
46
330
150
47
330
150
50
400
181
51
400
181
52
400
181
55
490
222
56
490
222
57
490
222
60
420
190
61
420
190
62
420
190
65
510
231
66
510
231
67
510
231
70
780
354
71
780
354
72
780
354
75
925
420
76
925
420
77
925
420
80
720
327
81
720
327
82
720
327
85
860
390
86
860
390
87
860
390

Check Motor Rotation

1. Engage the control power circuit breaker (CB2) located
inside the left hand side of the VFD enclosure.
2. Finally close the main motor disconnect (CB1) on the
front of the VFD enclosure.
3. The VFD checks for proper phase rotation as soon as
power is applied to the VFD and the PIC III controls
power up. The controls do not permit a start if the phase
rotation is not correct.
4. An alarm message will appear on the ICVC if the phase
rotation is incorrect. If this occurs, reverse any 2 of the 3
incoming power leads to the VFD and reapply power.
The motor is now ready for a rotation check.
5. After the default screen status message states 'Ready to
Start' press the
performs start-up checks.
6. When the VFD is energized and the motor begins to turn,
check for clockwise motor rotation. See Fig. 37.
Do not check motor rotation during coastdown. Rotation
may have reversed during equalization of vessel pressures.
Check Oil Pressure and Compressor Stop
1. When the motor is at full speed, note the OIL PRES-
SURE reading on the ICVC default screen. Normal
19XRV oil pressure readings are between 18 and 30 psid
(124 to 207 kPad). The oil pressure should be between 18
and 40 psid (124 to 276 kPad) on Frame 3 compressors
equipped with rolling element bearings.
2. Press the Stop button and listen for any unusual sounds
from the compressor as it coasts to a stop.
To Prevent Accidental Start-Up —
override setting may be entered to prevent accidental start-up
during service or whenever necessary. Access the MAINSTAT
screen and using the
highlight the CHILLER START/STOP parameter. Override the
current START value by pressing the
the
softkey followed by the
STOP
word SUPVSR! displays on the ICVC indicating the override
is in place.
To restart the chiller, the STOP override setting must be
removed. Access the MAINSTAT screen and using
or
softkeys highlight CHILLER START/STOP.
PREVIOUS
The 3 softkeys that appear represent 3 choices:
— forces the chiller ON
START
— forces the chiller OFF
STOP
— puts the chiller under remote or schedule
RELEASE
control
To return the chiller to normal control, press the
softkey followed by the
RELEASE
more information, see Local Start-Up, page 53.
The default ICVC screen message line indicates which
command is in effect.
70
softkey. The PIC III control
LOCAL
A chiller STOP
or
NEXT
PREVIOUS
softkey. Press
SELECT
softkey. The
ENTER
softkey. For
ENTER
softkeys,
NEXT

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents