1.2 Operating environment

Table 1-1 lists the operating environment specifications for the servers.
Table 1-1 Operating environment for Power 750 Express and Power 760
Description
Temperature
Relative humidity
Maximum dew point
Operating voltage
Operating frequency
Power consumption
Power source loading
Thermal output
Maximum altitude
Noise level for system unit
Operating
5 - 35 degrees C
(41 - 95 degrees F)
20 - 80%
29 degrees C
(84 degrees F)
200 - 240 V AC
50 - 60 ± 3 Hz
Power 750:
2400 watts maximum (system unit
with 32 cores installed)
Power 760:
2400 watts maximum (system unit
with 48 cores active)
Power 750:
2.45 kVA maximum (system unit
with 32 cores installed)
Power 760:
2.45 kVA maximum (system unit
with 48 cores active)
Power 750:
8,189 BTU/hr maximum (system
unit with 32 cores installed)
Power 760:
8,189 BTU/hr maximum (system
unit with 48 cores active)
3048 m
(10,000 ft)
Power 750 (system unit with 32 installed cores):
7.1 bels (operating or idle)
6.6 bels (operating or idle) with acoustic rack doors
Power 760 (system unit with 48 active cores):
7.1 bels (operating or idle)
6.6 bels (operating or idle) with acoustic rack doors
Non-operating
5 - 45 degrees C
(41 - 113 degrees F)
8 - 80%
28 degrees C
(82 degrees F)
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable