Mongoose M60i Owner's Operation Manual

Mongoose M60i Owner's Operation Manual

M60 series with built-in turbo timer
Hide thumbs Also See for M60i:

Advertisement

M60 Series
M60 Series
M60 Series
M60 Series
M60i
M60B, M60S
M60G/GNZ
WITH BUILT-IN TURBO TIMER
OWNERS OPERATION MANUAL
includes programming and wiring information
All models certified to AS/NZS4601 amendment 1 2003
M60B/S also certified to AS/NZS3749.1 2003 Class B
M60G also certified to AS/NZS3749.1 2003 Class A & B
These products should be professionally installed according to the
requirements of the AS/NZS 3749.2 1997 Installation Standard
3 STAR
4 STAR
5 STAR

Advertisement

Table of Contents
loading

Summary of Contents for Mongoose M60i

  • Page 1 M60 Series M60 Series M60 Series M60 Series M60i 3 STAR M60B, M60S 4 STAR M60G/GNZ 5 STAR WITH BUILT-IN TURBO TIMER OWNERS OPERATION MANUAL includes programming and wiring information All models certified to AS/NZS4601 amendment 1 2003 M60B/S also certified to AS/NZS3749.1 2003 Class B M60G also certified to AS/NZS3749.1 2003 Class A &...
  • Page 2: Remote Control

    TO REDUCE THE POSSIBILITY THE SIREN OF THE ALARM. PRESS OF FALSE ALARMS. BOTH AGAIN TO CANCEL BATTERY REPLACEMENT YOUR REMOTE CONTROL USES 2 x CR2016 LITHIUM COIN BATTERIES WHICH ARE AVAIL ABLE FROM YOUR MONGOOSE AGENT OR ELECTRONIC SHOPS.
  • Page 3: Table Of Contents

    CONTENTS Automatic engine immobilisation.. Noise pollution control..……. 9 Arming & Disarming ……....Indicator flashing……………… 10 Security re-arm ….……………..…. Dash mounted warning light… 10 Open circuit bypass……………….. Chirp confirmation…....Turbo timer…………………………. Panic…………..…..….. 11 Security re-arm……………….….. Boot release…………..…... 11 Silent arm/disarm ……………….… Programme options..…...
  • Page 4 THE AUTOMATIC ‘DUAL CIRCUIT’ ENGINE IMMOBILISER The engine will always be automatically immobilised 30 seconds after the ignition has been turned off. (Unless the built-in turbo timer is enabled – see page 6) This feature must not be turned off or defeated as it is an AS/NZS Standards or your insurance company requirement.
  • Page 5: Security Re-Arm

    ARMING Exit the vehicle and close all the doors (& bonnet & boot). Press button one on the remote control. The indicators flash once and the siren will chirp once to indicate that the system is armed. The dash board warning light, LED, will slow flash to indicate the system is armed. If your vehicle has central locking and it has been connected to this security system, the doors will lock at the same time as arming.
  • Page 6 BUILT-IN TURBO TIMER OPERATION The built-in turbo timer allows the engine to continue running for a pre-programmed time after the ignition has been turned off. This feature may be used to allow the vehicles turbo to cool down if excessively hot. In normal driving situations, the turbo timer should not be necessary. The timer is programmable for duration from 1 to 5 minutes - see ‘programming’.
  • Page 7: Silent Arm/Disarm

    OPEN CIRCUIT BYPASS If any door, the bonnet or boot is left open upon arming, the siren will chirp once as normal and then sound briefly to inform you a circuit is still open. If ignored, that circuit will not be protected. The open circuit (a door, the bonnet or boot) will automatically arm upon closure.
  • Page 8 SENSOR DISABLE BY REMOTE (alarm models only) There are times when you may wish to deactivate sensors (such as the impact sensor) to prevent false alarms. To turn sensors off, but still arm the rest of the system, press button one to arm the system and within 3 seconds, press button two.
  • Page 9: Arm Condition Memory

    GLASS BREAK SENSOR (M60G MODELS – optional on other models) This sensor is designed to trigger the alarm by detecting the sound of actual glass breakage. The sensitivity level is set by the installer and should be at its optimum. 2 STAGE IMPACT SENSOR (MODELS M60B/S/G) This sensor is designed to detect impacts to the vehicle.
  • Page 10: Indicator Flashing

    ALARM CHIRP CONFIRMATION & CODES 1 Chirp - Armed. 1 Chirp/short siren - indicates an open circuit when arming. 2 Chirps - Disarmed. 4 Chirps - Disarmed and indicates that the alarm has been triggered. Continual chirps - Ignition has been turned on when the engine is immobilised INDICATOR FLASHING (FUSE PROTECTED) When the siren sounds, the indicators flash simultaneously.
  • Page 11 ULTRASONIC SENSOR (optional) The ultrasonic sensor fill the interior of your vehicle with high frequency sound and is designed to trigger the alarm when the interior environment changes. Possible changes are the breaking or removal of glass, a door being opened, or even strong wind through a slightly open window. For the ultrasonic sensor to operate correctly ensure all doors and windows are closed when arming the alarm system.
  • Page 12: Programme Options

    PROGRAMME OPTIONS AUTOMATIC (LAST DOOR) ARMING - PROGRAMMABLE This feature is factory set in the ‘off’ position. You may have this programmed ‘on’ for added security. The alarm will then arm automatically 30 seconds after the last door is closed. The doors will not lock so that keys cannot be locked inside If the engine immobilises prior to the opening and closing of a door, this feature is bypassed.
  • Page 13: Remote Code Learning

    An irregular or interruption to the vehicle’s power supply may cause the remote not to work due to loss of remote memory. If your alarm fails to respond to the remote try re-learning them (may require the system to be overridden using the PIN code), or see your Mongoose dealer for assistance.
  • Page 14 TO LEARN REMOTE CONTROLS Disarm the system Drivers door must be open Turn the ignition ON/OFF 3 times (ignition remains off) The siren will chirp 3 times, the indicators will flash 3 times and the dashboard LED will light permanently to confirm you have entered remote code learning mode. Press button one on the 1 remote –...
  • Page 15: Emergency Override

    EMERGENCY OVERRIDE MONGOOSE EMERGENCY 4 DIGIT PIN CODE OVERRIDE DO NOT LOSE THIS CARD – KEEP IN A SECURE PLACE PIN CODE: PLEASE KEEP THIS CARD IN A SAFE PLACE Record the PIN on the ‘proof of purchase’ and in your mobile phone.
  • Page 16: Testing Your Alarm

    Without disarming the system, unlock and open a door with the ignition key - the alarm should • sound, excluding immobiliser model M60i. Check all other doors, bonnet and boot by the same procedure. Check the impact sensor, M60B/S/G, by giving the vehicle varying degrees of impact - be •...
  • Page 17 WIRING INFORMATION: Installation to be carried out by suitably qualified persons. MAIN MODULE The wires are printed for the function – remove labels when connecting; – TRIG (-) BONNET & BOOT TRIGGER INPUT (-) CH 2 OUTPUT – EG: BOOT RELEASE (+) 12v IGNITION INPUT GND ARM (-) GROUND WHEN ARMED OUTPUT...
  • Page 18 WIRING – Use immobiliser circuit #2 for built-in turbo timer...
  • Page 20 CENTRAL LOCKING CONNECTION OPTIONS...
  • Page 21 PROGRAMMING Drivers door must be open Within 15 seconds of opening the door, turn the ignition ON/OFF the number of times relative to the programme chart (eg: 4 times for ignition door locking) Siren will then chirp the same number of times as the programme number (eg: 4 times for ignition door locking), the lights also flash the same number of times Press button one to turn the feature "ON"...
  • Page 22: Warranty Terms & Conditions

    Mongoose warrants for a period of 36 months that it will make good without charge at Mongoose’s discretion, by repair or replacement with a reasonable equivalent, any defect in the product providing that; (a) the defect has been notified as soon as it is noticed to an authorised Mongoose installation centre, distributor or agent (in the first instance to the original installation centre).
  • Page 23 Whilst this security system provides a deterrent, it may not prevent theft or damage through wilful criminal intent. Mongoose does not by inference, intent or any other means guarantee that a vehicle fitted with one of it’s security systems will not be stolen, broken into, tampered with, or parts taken. Mongoose does not offer nor will pay compensation for any loss.
  • Page 24: Proof Of Purchase

    INSTALLER SIGNATURE:………………… OW NERS SIGNATURE:…………………… Please complete the above details which should be presented to your Mongoose dealer in the event that you require this product to be repaired under the terms of the ‘product warranty’. Refer ‘Warranty Conditions’. Failure to provide this ‘Proof of Purchase’ may result in rectification charges being made.

This manual is also suitable for:

M60bM60gM60sM60gnz

Table of Contents