IPL Errors (Continued)
Table 7-4
Error Text
There is no more heap
space available
Insufficient data available
to complete record
Invalid Symbol HEX file
Unrecognized or
unsupported HEX record
Invalid data in HEX file
Exceeded max size
Partition is not valid on
this device
Wrong destination code
File type does not support
IPL Auto Select
Non-contiguous record
found
Timed Out - No data
Fail: Buffer Overrun
Partition Table not Valid
Invalid file format

Creating a Splash Screen

The source bitmap files used to create the default splash screens for the mobile computer are supplied with the
DCP for MC9090c50. These files can be modified using any of the standard windows image editors, allowing
customization for particular customers.
To create a custom splash screen, perform the following steps:
Error
Number
-14
There is no more heap space available for the download procedure.
Restart IPL and retry the download. If the failure persists, contact
service with details of what is being downloaded.
-21
A Symbol HEX file download was attempted but the HEX file is invalid.
Ensure the file is in Symbol HEX file format.
-23
A Symbol HEX file download was attempted but the HEX file is invalid.
Ensure the file is in Symbol HEX file format.
-24
The Symbol HEX file being downloaded contains an invalid or
unrecognized HEX record. Ensure the file is in proper Symbol HEX file
format.
-25
The Symbol HEX file being downloaded contains invalid data. Ensure
the file is in proper Symbol HEX file format with valid HEX data.
-26
The download file is too large to fit into the space allocated for it. Either
make the file smaller or increase the space allocated for it by altering
the partition table.
-27
The downloaded file specifies a partition entry that does not exist on
the device. Only download files that are valid for this device, or change
the partition table so that the new file is valid on the device.
-28
A specific partition was chosen from the Main Menu (not Auto Select)
but the file selected for download was for another partition. Ensure that
the partition selected from the Main Menu matches the file selected for
download.
-29
Monitor, Power Micro and Partition Table cannot be loaded with Auto
Select. Select the appropriate area, and try again.
-30
A Symbol HEX file download was attempted but the HEX file is invalid.
Ensure the file is in Symbol HEX file format.
-31
IPL was waiting for data from the source device but timed out before
receiving any. Check the source device connectivity and retry.
-32
The serial port device could not keep up with incoming data. Retry the
serial download with a lower baud rate.
-33
The size of flash memory is different than that described in the partition
table. Retry the download with the correct partition table file.
-34
The file format is invalid. Only Symbol HEX files are supported by IPL.
Application Deployment for WinCE 5.0 7 - 19
Probable Cause