Daikin Super Multi Plus E-Series Service Manual page 43

Super multi plus e-series
Hide thumbs Also See for Super Multi Plus E-Series:
Table of Contents

Advertisement

Specifications
Model
Rated Capacity
Front Panel Color
m³/min
Air Flow Rate
(cfm)
Type
Fan
Motor Output
Speed
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
External Static Pressure
Moisture Removal
Heat Insulation
Liquid
Piping Connection
Gas
Drain
Drawing No.
Note:
30
CDKS25EAVMA
H
M
L
SL
W
Steps
5 Steps, Silent, Auto
A
0.47-0.48-0.49
W
%
67.7-64.3-61.2
Microcomputer Control
mm
200×700×620
mm
274×906×751
kg
kg
dBA
Pa
L/h
Both Liquid and Gas Pipes
mm
mm
mm
VP20 (O.D.
The operating sound is based on the rear side suction inlet and the external static pressure 30 Pa.
Operating sound for under side suction inlet: [operating sound for rear side suction inlet] +6 dB.
However, when installation to which the external static pressure becomes low is carried out,
6 dB or more may go up.
2.5kW Class
8.7 (307)
8.0 (282)
7.3 (258)
6.2 (219)
Sirocco Fan
62
70-71-72
21
29
35/33/31/29
30
1.2
φ
6.4
φ
9.5
φ
φ
26 / I.D.
20)
3D051142
SiEN18-622
50Hz 220-230-240V
CDKS35EAVMA
3.5kW Class
8.7 (307)
8.0 (282)
7.3 (258)
6.2 (219)
Sirocco Fan
62
5 Steps, Silent, Auto
0.47-0.48-0.49
70-71-72
67.7-64.3-61.2
Microcomputer Control
200×700×620
274×906×751
21
29
35/33/31/29
30
1.9
Both Liquid and Gas Pipes
φ
6.4
φ
9.5
φ
φ
VP20 (O.D.
26 / I.D.
20)
3D051143
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Specifications

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents