Specifications
Model
Rated Capacity
Front Panel Color
m³/min
Air Flow Rates
(cfm)
Type
Fan
Motor Output
Speed
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
External Static Pressure
Moisture Removal
Heat Insulation
Liquid
Piping Connection
Gas
Drain
Drawing No.
Model
Rated Capacity
Front Panel Color
m³/min
Air Flow Rates
(cfm)
Type
Fan
Motor Output
Speed
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
External Static Pressure
Moisture Removal
Heat Insulation
Liquid
Piping Connection
Gas
Drain
Drawing No.
Note:
44
CDXS25CVMA
Cooling
H
9.5 (335)
M
8.8 (311)
L
8.0 (282)
SL
6.7 (237)
W
Steps
5 Steps, Silent, Auto
Removable-Washable-Mildew Proof
A
0.47
W
100
%
92.5
Microcomputer Control
mm
200×900×620
mm
266×1,106×751
kg
kg
dBA
35/33/31/29
Pa
L/h
1.2
Both Liquid and Gas Pipes
mm
mm
mm
VP20 (O.D
CDXS50CVMA
Cooling
H
12.0 (424)
M
11.0 (388)
L
10.0 (353)
SL
8.4 (297)
W
Steps
5 Steps, Silent, Auto
Removable-Washable-Mildew Proof
A
0.64
W
140
%
95.1
Microcomputer Control
mm
200×900×620
mm
266×1,106×751
kg
kg
dBA
37/35/33/31
Pa
L/h
2.9
Both Liquid and Gas Pipes
mm
mm
mm
VP20 (O.D
The operating sound is based on the rear side suction inlet and the external static pressure 40 Pa.
Operating sound for under side suction inlet: [ operating sound for rear side suction inlet ]+5 dB.
However, when installation to which the external static pressure becomes low is carried out,
5 dB or more may go up.
Heating
2.5kW Class
9.5 (335)
8.8 (311)
8.0 (282)
6.7 (237)
Sirocco Fan
62
0.47
100
92.5
25
31
35/33/31/29
40
φ
6.4
φ
9.5
φ
φ
26 / I.D
20)
3D046469
Heating
5.0kW Class
12.0 (424)
11.0 (388)
10.0 (353)
8.4 (297)
Sirocco Fan
130
0.64
140
95.1
27
34
37/35/33/31
40
φ
6.4
φ
12.7
φ
φ
26 / I.D
20)
3D046471
SiEN18-622
50Hz 230V
CDXS35CVMA
Cooling
Heating
3.5kW Class
10.0 (353)
10.0 (353)
9.3 (328)
9.3 (328)
8.5 (300)
8.5 (300)
7.0 (247)
7.0 (247)
Sirocco Fan
62
5 Steps, Silent, Auto
Removable-Washable-Mildew Proof
0.47
0.47
100
100
92.5
92.5
Microcomputer Control
200×900×620
266×1,106×751
25
31
35/33/31/29
35/33/31/29
40
1.9
Both Liquid and Gas Pipes
φ
6.4
φ
9.5
φ
φ
VP20 (O.D
26 / I.D
20)
3D046470
CDXS60CVMA
Cooling
Heating
6.0kW Class
16.0 (565)
16.0 (565)
14.8 (523)
14.8 (523)
13.5 (477)
13.5 (477)
11.2 (395)
11.2 (395)
Sirocco Fan
130
5 Steps, Silent, Auto
Removable-Washable-Mildew Proof
0.74
0.74
160
160
94.0
94.0
Microcomputer Control
200×1,100×620
266×1,306×751
30
37
38/36/34/32
38/36/34/32
40
3.9
Both Liquid and Gas Pipes
φ
6.4
φ
12.7
φ
φ
VP20 (O.D
26 / I.D
20)
3D046472
Conversion Formulae