IBM xSeries 346 Hardware Maintenance Manual And Troubleshooting Manual page 90

Types 8840 and 1880
Hide thumbs Also See for xSeries 346:
Table of Contents

Advertisement

Note: See "System" on page 106 to determine which components a field service technician should replace.
Error code/symptom
1303
2
(I
C cable from system board to power
cage assembly not found)
1304
2
(I
C cable to diagnostic LED board not
found)
1600
(The system management processor is not
functioning) Before replacing a FRU,
remove the ac power to the server, wait
20 seconds; then, reconnect the ac power.
Wait 30 seconds; then, turn on the server.
1601
(The system is able to communicate to the
system management processor, but the
system management processor failed to
respond at the start of POST.) Complete
the following steps before replacing a
FRU:
1. Remove the ac power to the server,
wait 20 seconds; then, reconnect the
ac power. Wait 30 seconds; then, turn
on the server.
2. Flash update the system management
processor.
1602
(Cable for optional service processor
adapter not installed)
1762
(Hard disk configuration error)
178X
(Fixed disk error)
1800
(No more hardware interrupt available for
PCI adapter)
80
xSeries 346 Types 8840 and 1880: Hardware Maintenance Manual and Troubleshooting Guide
FRU/action
1. Cable
2. Power-cage assembly
3. System board
1. Power switch assembly
2. System board
System board
1. Remote Supervisor Adapter, if installed
2. System board
Disconnect all server and option power cords from server, wait 30
seconds, reconnect, and retry.
1. Hard disk drive.
2. Hard disk cables.
3. Run the Configuration/Setup Utility program.
4. Hard disk adapter.
5. SCSI backplane.
6. System board.
1. Hard disk cables.
2. Run diagnostics.
3. Hard disk adapter.
4. Hard disk drive.
5. System board.
1. Run the Configuration/Setup Utility program.
2. Failing adapter.
3. System board.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents