Note: See "System" on page 106 to determine which components a field service technician should replace.
Error code/symptom
262
(DRAM parity configuration error)
289
(DIMM disabled by POST or user)
301
(Keyboard or keyboard controller error)
303
(Keyboard controller error)
602
(Invalid diskette boot record)
604
(Diskette drive error)
605
(Unlock failure)
662
(Diskette drive configuration error)
762
(Coprocessor configuration error)
962
(Parallel port error)
11XX
(System board serial port 1 or 2 error)
1301
2
(I
C cable to front panel not found)
1302
2
(I
C cable from system board to power on
and reset switches not found)
FRU/action
1. Run the Configuration/Setup Utility program.
2. Battery.
3. System board.
1. Run the Configuration/Setup Utility program, if the DIMM was
disabled by the user.
2. Disabled DIMM, if not disabled by user.
1. Keyboard
2. System board
System board
1. Diskette
2. Diskette drive
3. Cable
4. System board
1. Run the Configuration/Setup Utility program and diagnostics.
2. Diskette drive.
3. Drive cable.
4. System board.
1. Diskette drive
2. Drive cable
3. System board
1. Run the Configuration/Setup Utility program and diagnostics.
2. Diskette drive.
3. Drive cable.
4. System board.
1. Run the Configuration/Setup Utility program.
2. Battery.
3. Microprocessor.
1. Disconnect the external cable on the parallel port.
2. Run the Configuration/Setup Utility program.
3. System board.
1. Disconnect the external cable on the serial port.
2. Run the Configuration/Setup Utility program.
3. System board.
1. Cable
2. Front panel
3. Power switch assembly
4. System board
1. Cable
2. Power switch assembly
3. System board
Chapter 6. Symptom-to-FRU index