Rings And Tones; Ring Cycles; Tones; Table 3.16 System Ring Cycles - Samsung OfficeServ 7200 General Description Manual

Enterprise ip solutions
Hide thumbs Also See for OfficeServ 7200:
Table of Contents

Advertisement

CHAPTER 3. OfficeServ 7200 Specifications
4

Rings and Tones

4.1

Ring Cycles

The OfficeServ 7200 provides trunk line, station, door and alarm rings. The on/off
cycle for each ring type is shown in Table 3.16.
Ring
Trunk line ring
Station ring
Door ring
Alarm ring
4.2

Tones

For system ring signals, the output voltage is 75 V and the frequency is 20 Hz.
The OfficeServ 7200 provides users with various tones to notify them of the status
of functions and provide feedback. The on/off cycles of currently specified tones
are shown in Table 3.17.
Dial tone
Busy Tone
Do Not Disturb tone
Ring Back tone
Call Park tone
Confirmation/Caution/Barge-In tone
Call Back/Hold tone
Ring Back tone
Error/Number Unobtainable tone
Message Camp On tone
Page 3-10

Table 3.16 System Ring Cycles

400/200/400/3000 ms
1000/2000 ms
400/200/400/200/400/2000 ms
400/200/400/200/400/200/400/1000 ms
Ring On/Off Cycle
The on/off cycle can be adjusted by changing the values in the system software.

Table 3.17 System Tone Cycles

Tone
OfficeServ 7200 General Description Guide
On/Off Cycle
On/Off Cycle
1000/250 ms
500/500 ms
250/250 ms
1000/2000 ms
Continuous
50/50 ms
500/3500 ms
1000/2000 ms
250/250 ms
Continuous
© Samsung Business Communications

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents