Operation

To perform a test run the device can be operated
manually using the selection buttons. For this
press and hold the selection button (>1.6 s) until
the device is switched.
Manual operation is also possible via external
buttons. The external buttons can not be used for
the operation modes ON/OFF (2-button-control)
and UP/STOPP/DOWN (4-button-control).
The switching via external buttons
has preference over the switching by
radio control. This means that
operations which have been
switched with the external buttons
can not be overruled by switching via
radio control.
4

Programming

4.1 Operating Controls
LED
Switching Output 1
Selection Button
Switching Output 1
Rotary Switch
Mode of Operation
Programming
button
6
select 1
µ
1
prog.
L
10A
In order to operate the receiver with radio
transmitters the transmission code of a
transmitter has to be memorized for the desired
mode of operation.
Because one transmission code is allocated to
each pair of buttons, only one button has to be
pressed to memorize the transmission code.
While operating the device with radio
transmitters and during the memorizing process
the LED-Display flashes to indicate that the
radio connection is estabished.
230V ~ 50Hz
select 2
µ
2
2'
L
L
10A
Selection Button
Switching Output 2
LED-Anzeige
Switching Output 2
Rotary Switch
Time Function
LED
Reception Activity
LED
Power Supply