Start-Up; Selecting The Location - Eldat RCU08 Operating Instructions Manual

Universal-receiver 2-channel ip66
Table of Contents

Advertisement

32 transmission codes can be memorized and
for each transmission code an operating mode
as well as a specific time function for the oper-
ating time and switching time can be defined.
The following operating modes can be se-
lected:
ON/OFF (2-button-control): for switching ON
use transmitter button A or C, for switching OFF
use transmitter button B or D.
ON (1-button-control): the consumer can be
switched ON with any separately learnt
transmitter button. An operating time of either
1.5 or 3 s can be selected.
OFF (1-button-control): the consumer can be
switched OFF with any separately learnt
transmitter button. An operating time of either
1.5 or 3 s can be selected.
Timer (1-button-control): the relay can be
switched with any transmitter button according
to the desired switching time T.
ON/OFF (1-button-control): using the toggle
function the consumer can be switched ON or
OFF by repeatedly pressing the transmitter
button.
UP/STOP/DOWN (2-button-control): use
transmitter button A or C to open awnings, the
buttons for the opposite direction B or D can be
used to drive the motor in the opposite direction
or stop the awning.
UP (1-button-control): use any transmitter button
to open the awning.
DOWN (1-button-control): use any transmitter
button to close the awning.
STOP (1-button-control): use any transmitter
button to stop the awning.
UP/STOP/DOWN (4-button control): use
transmitter button A to open awnings, button C
or D to stop it. Button B closes the awning.
2

Start-Up

2.1

Selecting the Location

Choosing the location for the installation please
take into account that the reception quality and
sensitivity of the Universal Receiver RCU08 can
be disturbed by several factors:
equipment and systems without interference
suppression
other transmitters within the frequency range
atmospheric conditions and other factors.
Transmitter and receiver should be located in a
way that the shortest distance between them (air
line distance) is not or only slightly disturbed by
brick walls or other absorbing materials or any
disturbance. This way losses due to absorption
which influence the operation range of the
receiver can be reduced to a minimum.
Following values can be taken for reference:
Material
air/no obstacle
wood, hard plaster
brick/concrete
reinforced concrete
metal walls, metal gratings
Do not mount the receiver or the aerials on the
back of metal surfaces on the floor or in recesses
to avoid radio shadows.
When mounting the unit on metal surfaces, a
minimal distance of 10 cm should be kept.
Changes such as lengthening, shortening,
bending etc. may influence the receiving
properties considerably.
In case any problems occur contact you retailer
or for more information see: „
Range
100%
80–95%
60–90%
10–50%
0–10%
www.eldat.de
"
3