System settings (Service menu – Settings)
6
6
System settings (Service menu – Settings)
B Press
+
B Turn the
rotary selector to the left until settings is selected.
B Press
to open menu SERVICE\SETTINGS.
Note that the menu items shown will vary depending on the heating system.

6.1 System data

B Press
button to select plant data.
The menu SETTINGS\SYSTEM opens.
Menu item
Have you installed a module for
the low loss header?
Is a sensor for a low loss header
connected?
Is heating circuit 1 installed
(unmixed heating circuit)?
How many mixed heating circuits
are installed?
Have you installed a solar
module?
Table 10 Navigator for service menu SETTINGS\SYSTEM
26
+
simultaneously, to open the SERVICE MENU.
Input
range
Yes, No
No,
at the
boiler, at
the low loss
header
module
Yes, No
0 to 3
Yes, No
Standard
setting
Other information
No
In association with MCM10 the
setting is automatically set to "Yes";
screen is hidden.
No
If a low loss header module is used,
connect the temperature sensor to
the low loss header module.
Yes
0
Setting the address on the rotary
coding selector of the mixer module
(basic setting HK2).
1)
No
SERVICE MENU
quick operation
B
settings
diagnosis
servicing
SERVICE\SETTINGS
B
plant data
boiler data
domestic hot water
heating circuit 1
1)2)
1)
Logamatic EMS – 6 720 801 387 (2011/05)
3) 4)