System settings (Service menu – Settings)
6

6.7 RC35 calibration

B Turn the
rotary selector to the left until RC35 calibration is selected
B Press button
The menu for SETTING/RC35 CAL is opened.
Menu item
RC35 calibration
Table 18 Navigator for service menu SETTINGS\CALIB. RC35
Calibrating the displayed room temperature (calibration)
If there is a separate thermometer near the programming unit, it may show a different room
temperature to that shown on the programming unit. You can use this function to adjust ("calibrate")
the programming unit to match the thermometer.
Before adjusting the room temperature, consider the following:
• Is the thermometer more accurate than the programming unit?
• Is the thermometer located close to programming unit so that they are both subject to the same
heat influences (e.g. sunlight, fireplace)?
A thermometer may indicate temperature fluctuations more slowly or rapidly than the
programming unit.
B Therefore, never calibrate the programming unit during phases when the heating
system is cooling down or heating up.
Example: if the thermometer is showing a temperature 0.5 °C higher than the programming unit,
enter +0.5 K as the calibration value.
44
to select RC35 calibration.
Input range
– 5.0 K to +5.0 K
Standard setting
0.0 K
Logamatic EMS – 6 720 801 387 (2011/05)
SERVICE\SETTINGS