Hybrid - Bosch RC35 Installation And Service Instructions Manual

Logamatic ems programming unit room controller
Table of Contents

Advertisement

6.2 Hybrid

B Turn the
rotary selector to the left until Hybrid is selected.
B Press
to select Hybrid.
The SETTINGS\HYBRID menu is opened
Menu item
Is there a buffer in the
system?
Triggering of boiler / heat
pump depends on:
Energy price ratio for
electricity / fossil fuel
What is the primary energy
factor for the fossil fuel?
What is the primary energy
factor for the electrical
energy?
What should the dual-mode
switching threshold be?
How is the pump on the
HM10 integrated
hydraulically?
By what amount of time
should the boiler switch-in
be delayed?
Temperature difference for
delayed boiler switch-in?
Table 12 Navigator for Service menu\Settings\Hybrid
You can find explanations on the settings in the documents for the hybrid system.
Logamatic EMS – 6 720 801 387 (2011/05)
System settings (Service menu – Settings)
Input range
Yes, No
Environmental factors,
costs, switching threshold,
environment and costs
0.0 to19.9
0.0 to 5.0
0.0 to 5.0
-20 °C to +20 °C
serial, parallel
5 to 120 minutes
1K to 99K
SERVICE\SETTINGS
plant data
B
hybrid
boiler data
heating circuit 1
Standard setting
no
Environment
3.3
1.1
2.6
+6 °C
serial
6
Other
information
29