Ucd Group - Panasonic KX-TA308 Installation Manual

Advanced hybrid system
Hide thumbs Also See for KX-TA308:
Table of Contents

Advertisement

4.2
System Programming

[520] UCD Group*

Assigns one extension group which works as the UCD group.
5
Default
• Feature Reference
Section 3, Features
Uniform Call Distribution (UCD)
[521] UCD Busy Waiting Time*
Assigns the length of time the system holds an incoming outside call via the UCD feature
when all extensions in the UCD group are busy. When the programmed time expires, the
call will be intercepted or disconnected according to program [523] "UCD Busy Mode".
5
* Waiting time: 1 through 32 (minutes) / 1 through 59 (seconds)
Default
• Feature Reference
Section 3, Features
Uniform Call Distribution (UCD)
[522] UCD OGM Message Interval Time*
Assigns interval time between sending UCD outgoing messages to an incoming outside call
via the UCD feature when all extensions in the UCD group are busy. The UCD outgoing
message is repeated during the time programmed in [521] "UCD Busy Waiting Time".
5
Default
• Feature Reference
Section 3, Features
Uniform Call Distribution (UCD)
*
1
: Required only when the optional OGM/FAX Detection
Card is installed.
1
2
0
NEXT
Extension group number 1
2
1
NEXT
10 minutes
2
2
NEXT
1 minute
extension group no.
(1···8)
1
waiting time*
SELECT
(min/sec)
1
SELECT
STORE
(30 sec/1/
1.5/2 min)
[520]-[522]
END
STORE
STORE
END
END
System Programming
4-67

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-ta616

Table of Contents