INSTALLATION INSTRUCTIONS

This manual covers unpacking and inspection, selecting location, installing unit, and preparing for operation.
R
I
EMOVE
CEMAKER FROM
Keep unit in the upright position, remove carton and pallet from unit and inspect unit for damage. Upon inspection of
unit, if any damage is found, file a claim with carrier immediately.
C
R
ABINET
EMOVAL
1. Front Panel—Remove 4 screws and pull forward.
2. Top Panel—Remove screws and lift upward. 4 screws 500/700, 6 screws 1000.
3. Side Panel—Remove 4 screws and pull forward.
4. Back Panel—Should not be removed.
P
REPARATION OF
The refrigeration system on air cooled units requires airflow, so a well ventilated area should be chosen.
1. A minimum of 12 inches must be maintained, free of any obstructions, for air intake. A minimum of 4 inches
clearance is required for air exhaust.
2. For WCC500A units, maintain minimum clearances of 18 inches on top and 6 inches on sides as well as in the
rear for sufficient air flow.
3. The unit can be installed either on an ice storage bin or ice dispenser using the proper adapter kits. (Refer to
sales literature for information.) The install is kit provided with each icemaker and adapter kits will supply every-
thing to locate unit correctly. In all cases the icemaker should be sealed all around the base with an NSF listed
sealant. (63804815B)
W
I
H
ATER
NLET
OOK
!
WARNING:
IIt is the responsibility of the installer to ensure that the water supply to the dispensing equipment is provided with
protection back flow by an air gap as defined in ANSI A 112.1.2-1979; or an approved vacuum breaker or other such
method as proved effective by test and must comply with all federal, state and local codes.
Failure to comply could result in serious injury, death or damage to the equipment.
Water pipe connections and fixtures directly connected to a potable water supply
maintained according to Federal, State and Local
!
WARNING:
1. Water Inlet—fitting is a 1/4 SAE male flare located at the rear of the unit. Connect water supply with a 1/4 SAE
flare nut and 1/4" copper or flexible tubing or larger.
2. Water Pressure—Unless otherwise specified, the unit is designed to operate on water pressures between
137.9 kpa and 620.5kpa (NOTE: for pressures above 90 P.S.I. a regulator must be installed.)
3. Condenser Inlet Connections—Use a separate 3/8" copper line or larger water line. Connect to 3/8 FPT fit-
ting on water modulating valve.
4. Filter/Conditioners are recommended on supply lines to icemakers. Never run the water supply to water cooled
condenser through filter/conditioner, it uses up the cartridge unnecessarily and a saturated cartridge can
starve the icemaker causing premature component damage. Separate water supplies are recommended.
© 2004-2013, IMI Cornelius Inc.
C
ARTON
I
S
NSTALLATION
ITE
U
P
laws.
Continuous Flow Icemaker Installation Manual
shall be sized, installed and
- 3 -
Publication Number: 630460174INS