Cornelius 1000 Series Installation Manual
Cornelius 1000 Series Installation Manual

Cornelius 1000 Series Installation Manual

Continuous flow icemaker
Hide thumbs Also See for 1000 Series:

Advertisement

C
F
ONTINUOUS
LOW
This manual covers unpacking and inspection, selecting location, installing unit, and preparing for
operation.
R
I
EMOVE
CEMAKER FROM
1.
Keep unit in the upright position, remove carton and pallet from unit and inspect unit for damage.
Upon inspection of unit, if any damage is found, file a claim with carrier immediately.
C
R
ABINET
EMOVAL
Front Panel—Remove 4 screws and pull forward.
1.
Top Panel—Remove screws and lift upward. 4 screws 500/700, 6 screws 1000.
2.
Side Panel—Remove 4 screws and pull forward.
3.
Back Panel—Should not be removed.
4.
P
REPARATION OF
1.
The refrigeration system on air cooled units requires airflow, so a well ventilated area should be
chosen. A minimum of 6 inches must be maintained, free of any obstructions, for air intake. A
minimum of 4 inches clearance is required for air exhaust.
2.
The unit can be installed either on an ice storage bin or ice dispenser using the proper adapter kits.
(Refer to sales literature for information.) The install is kit provided with each icemaker and adapter
kits will supply everything to locate unit correctly. In all cases the icemaker should be sealed all
around the base with an NSF listed sealant. (63804815B)
W
I
H
ATER
NLET
OOK
Water Inlet—fitting is a 1/4 SAE male flare located at the rear of the unit. Connect water supply
1.
with a 1/4 SAE flare nut and 1/4" copper or flexible tubing or larger.
Water Pressure—Unless otherwise specified, the unit is designed to operate on water pressures
2.
between 10 P.S.I. and 90 P.S.I. (NOTE: for pressures above 90 P.S.I. a regulator must be installed.)
Condenser Inlet Connections—Use a separate 3/8" copper line or larger water line. Connect to 3/
3.
8 FPT fitting on water modulating valve.
4.
Filter/Conditioners are recommended on supply lines to icemakers. Never run the water supply to
water cooled condenser through filter/conditioner, it uses up the cartridge unnecessarily and a
saturated cartridge can starve the icemaker causing premature component damage. Separate
water supplies are recommended.
NOTE: Unit must be installed per local plumbing code BOCA.
D
C
RAIN
ONNECTION
Overflow Line—is a 3/8" I.D. flexible tube located at the rear of the unit. Extend this line to proper
1.
drain.
Condenser Outlet—is a 3/8" FPT located on the rear panel.
2.
NOTE: Unit must be installed per local plumbing code. BOCA.
E
S
LECTRICAL
UPPLY
Power Access—is provided with a 7/8" diameter. knockout hole in the rear panel. Route incoming
1.
power in conduit, through rear panel to icemaker electrical control box. Make connections to wires
provided in the control box and ground lug/screw.
Fused Line—should be checked and sized according to electrical rating shown on unit nameplate.
2.
Release Date: July 1, 2008
© 2004-2008, IMI Cornelius Inc.
INSTALLATION MANUAL
I
S
CEMAKERS
ERIES
C
ARTON
I
S
NSTALLATION
ITE
U
P
www.cornelius.com
Continuous Flow Icemaker Installation Manual
500, 700, 1000,
- 1 -
2000
AND
Revision: C
Publication Number: 630460174INS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Cornelius 1000 Series

  • Page 1 Fused Line—should be checked and sized according to electrical rating shown on unit nameplate. www.cornelius.com Release Date: July 1, 2008 Revision: C © 2004-2008, IMI Cornelius Inc. - 1 - Publication Number: 630460174INS...
  • Page 2 The WCC2001QT-R is equipped with an auger motor run delay. The auger motors will run after compressor shut down for approximately two minutes. This is to clear out the evaporators and is normal. Publication Number: 630460174INS - 2 - © 2004-2008, IMI Cornelius Inc.

This manual is also suitable for:

700 series500 series2000 series

Table of Contents