Initial Start Up, Checks And Adjustment Instructions; For Wcc2001Qt-R Only - Cornelius 500 Series Installation Manual

Continuous flow icemaker
Hide thumbs Also See for 500 Series:
Table of Contents

Advertisement

Continuous Flow Icemaker Installation Manual
I
S
U
NITIAL
TART
P
NOTE: Do not start unit before completing installation steps on the previous page.
Turn on water supply (if unit is water cooled turn water on to condenser also) turn on main power switch (located on
top of electrical box), and make the following system checks:
NOTE: If unit will not start be sure water reservoir is full. Low water safety control must be properly
adjusted to start and shut down unit. If water level drops below bottom of reservoir, unit
must shut down. Adjustment is made by moving magnet up or down.
Water Level—If necessary adjust float by bending float arm up or down as needed, push float assembly down until
unit stops running. Release float and unit will restart. Keep water in reservoir at level line while unit is in operation.
Low Water Safety Control—Adjust magnet by bending magnet arm as needed to shut unit down if water level
drops below bottom of reservoir.
Bin Control—Place ice around probe, unit should shut down in one minute. Remove ice from around probe, unit
should start in two minutes.
Water modulating valve (water cooled units only)—Opening point of condenser water modulating valve should
be set to maintain proper operating pressure in the refrigeration system high side. Closing point of valve should be
set low enough to close valve during compressor stand by periods. To raise, turn counterclockwise, to lower turn
clockwise.
NOTE: If any of these checks or adjustments cannot be achieved, refer to Service Manual or call for
factory assistance at 1-800-238-3600.

For WCC2001QT-R Only:

1. The WCC2001QT-R is equipped with a compressor start delay. The auger motors will run before compressor
start for approximately two minutes. This is to clear out the evaporators and is normal.
2. The WCC2001QT-R is equipped with an auger motor run delay. The auger motors will run after compressor
shut down for approximately two minutes. This is to clear out the evaporators and is normal.